Data Sheet  
Naos Raptor 60A: Non Isolated Power Modules  
December 6, 2010  
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current  
the Tunable LoopTM feature described later in this  
data sheet.  
Feature Descriptions  
Remote On/Off  
Safety Considerations  
The Naos Raptor 60A power modules feature a  
remote On/Off pin with positive logic. If not using the  
On/Off pin, leave the pin open (the module will be ON,  
except for the -49 option modules where leaving the  
pin open will cause the module to remain OFF). The  
On/Off signal (VOn/Off) is referenced to ground.  
For safety agency approval the power module must  
be installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-1-  
03, and VDE 0850:2001-12 (EN60950-1) Licensed.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power  
module has extra-low voltage (ELV) outputs when all  
inputs are ELV.  
During a Logic High on the On/Off pin, the module  
remains ON. During Logic-Low, the module is turned  
OFF.  
5V  
MODULE  
An input fuse for the module is recommended. Due to  
the wide input voltage and output voltage ranges of  
the module, different fuse ratings are recommended  
as shown in Table 1. These are suggested  
2K  
2K  
100K  
ENABLE  
“maximum” fuse ratings. However, for optimum circuit  
protection, the fuse value should not be any larger  
than required in the end application. As an option to  
using a fuse, no fuse is required, if the module is  
ON/OFF  
2.2K  
47K  
2.2K  
47K  
GND  
1. powered by a power source with current limit  
protection set point less than the protection  
device value listed in Table 1, and  
2. the module is evaluated in the end-use  
equipment.  
Figure 41. Remote On/Off Implementation. The  
100K resistor is absent in the -49 option modules.  
Table 1.  
Input  
Voltage  
(VDC)  
10.1 to 14  
6.51 to 10  
5 to 6.5  
Output Voltage (VDC)  
Overcurrent Protection  
0.59 to 1.3  
1.31 to 2.7  
2.71 to 5.0  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
25A  
40A  
40A  
50A  
70A  
90A  
80A  
100A  
100A  
current-limiting circuitry and can endure current  
limiting continuously. At the point of current-limit  
inception, the unit enters hiccup mode. The unit  
operates normally once the output current is brought  
back into its specified range. The typical average  
output current during hiccup is 10% of Io,max  
.
Over Temperature Protection  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shut down if the overtemperature threshold of 135ºC  
is exceeded at the thermal reference point Tred. The  
thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating.  
Once the unit goes into thermal shutdown, it will then  
wait to cool before attempting to restart.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  