Data Sheet  
Naos Raptor 20A: Non Isolated Power Module:  
July 28, 2009  
4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 20A output current  
Safety Considerations  
Feature Descriptions  
For safety agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards,  
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE  
0850:2001-12 (EN60950-1) Licensed.  
Enable (Remote On/Off)  
The Naos Raptor 20A modules feature an Enable pin with  
positive logic for remote On/Off operation. If not using the  
Enable pin, leave the pin open (the module will be ON,  
except for the -49 option modules where leaving the pin  
open will cause the module to remain OFF). The Enable  
signal (VEnable) is referenced to ground.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
During a Logic High on the Enable pin, the module  
remains ON. During Logic-Low, the module is turned  
OFF.  
An input fuse for the module is recommended. Due to the  
wide input voltage and output voltage ranges of the  
module, different fuse ratings are recommended as  
shown in Table 1. These are suggested “maximum” fuse  
ratings. However, for optimum circuit protection, the fuse  
value should not be any larger than required in the end  
application. As an option to using a fuse, no fuse is  
required, if the module is  
MODULE  
R1  
7.5K  
ON/OFF  
GND  
ENABLE  
R2  
100k  
C1  
1000p  
1. powered by a power source with current limit  
protection set point less than the protection  
device value listed in Table 1, and  
2. the module is evaluated in the end-use  
equipment.  
Figure 47. Remote On/Off Implementation.  
Components R2 and C1 are only present in the -49Z  
option module.  
Table 1.  
Input  
Voltage  
Output Voltage (VDC)  
Overcurrent Protection  
0.59 to 1.3 1.31 to 2.7 2.71 to 5.0 5.1 to 6  
(VDC)  
10.1 to 14  
6.51 to 10  
4.5 to 6.5  
5A  
6.3A  
10A  
10A  
15A  
20A  
15A  
25A  
30A  
20A  
30A  
NA  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally once  
the output current is brought back into its specified range.  
The typical average output current during hiccup is 10%  
of Io,max  
.
Overtemperature Protection  
To provide protection in a fault condition, these modules  
are equipped with a thermal shutdown circuit. The unit  
will shut down if the overtemperature threshold of 130ºC  
is exceeded at the thermal reference point Tref. The  
thermal shutdown is not intended as a guarantee that the  
unit will survive temperatures beyond its rating. Once the  
unit goes into thermal shutdown it will then wait to cool  
before attempting to restart.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will begin  
to operate at an input voltage above the undervoltage  
lockout turn-on threshold.  