4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 10A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
All
T
A
-40
85
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
15
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=4.5V to 14V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 9Vdc, I
O
= 0, module enabled)
(V
IN
= 12Vdc, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 12Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to
14V
,
I
O
= I
Omax
; See Test Configurations)
Input Ripple Rejection (120Hz)
All
All
All
It
45
40
2
Device
All
All
Symbol
V
IN
I
IN,max
Min
4.5
Typ
12
Max
14
10
Unit
Vdc
Adc
V
O,set
= 0.6 Vdc
V
O,set
= 5.0Vdc
All
I
IN,No load
I
IN,No load
I
IN,stand-by
36
86
1
mA
mA
mA
2
1
As
mAp-p
dB
LINEAGE