NH033x-L and NH050x-L Series Power Modules:  
5 Vdc Input; 1.2 Vdc to 3.3 Vdc Output; 10 A and 15 A  
Data Sheet  
March 2010  
Proper cooling can be verified by measuring the power  
module’s temperature at lead 7 of Q32 as shown in  
Figure 41.  
Feature Descriptions (continued)  
Overtemperature Protection  
To provide additional protection in a fault condition, the  
unit is equipped with a nonlatched thermal shutdown  
circuit. The shutdown circuit engages when Q32  
exceeds approximately 120 °C. The unit attempts to  
restart when Q32 cools down. The unit cycles on and  
off if the fault condition continues to exist. Recovery  
from shutdown is accomplished when the cause of the  
overheating condition is removed.  
Q32  
LEAD #7  
8-1149(C).b  
Thermal Considerations  
Figure 41. Temperature Measurement Location  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation of the unit.  
Heat is removed by conduction, convection, and radia-  
tion to the surrounding environment.  
The temperature at this location should not exceed  
115 °C at full power. The output power of the module  
should not exceed the rated power.  
The thermal data presented is based on measure-  
ments taken in a wind tunnel. The test setup shown in  
Figure 40 was used to collect data for Figures 50 and  
51. Note that the airflow is parallel to the long axis of  
the module. The derating data applies to airflow along  
either direction of the module’s long axis.  
Convection Requirements for Cooling  
To predict the approximate cooling needed for the mod-  
ule, determine the power dissipated as heat by the unit  
for the particular application. Figures 42 through 49  
show typical power dissipation for the module over a  
range of output currents.  
The module runs cooler when it is rotated 90° from the  
direction shown in Figure 40. This thermally preferred  
orientation increases the maximum ambient tempera-  
tures 4 °C to 5 °C from the maximum values shown in  
Figures 50 and 51.  
3.5  
3.0  
2.5  
VI= 5.5 V  
VI= 5.0 V  
2.0  
VI = 4.5 V  
203.2 (8.0)  
1.5  
AIRFLOW  
1.0  
0.5  
0
1
2
3
4
5
6
8
9
10  
7
OUTPUT CURRENT, IO (A)  
AIR VELOCITY  
AND AMBIENT  
8-2446(C)  
POWER MODULE  
25.4 (1.0)  
TEMPERATURE  
MEASURED HERE  
Figure 42. NH033M-L Typical Power Dissipation vs.  
Output Current, TA = 25 °C  
76.2 (3.0)  
8-1199(C).a  
Note: Dimensions are in millimeters and (inches).  
Figure 40. Thermal Test Setup  
14  
Lineage Power  