Data Sheet
October 14, 2009
Absolute Maximum Ratings
NH020-Series Power SIPs:
5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Parameter
Input Voltage:
Continuous
Operating Ambient Temperature*
Storage Temperature
On/Off Terminal Voltage
Symbol
VIN
T
Q31
Tstg
Von/off
Min
0
–40/0
–55
—
†
Max
7.0
115
125
6.0
Unit
Vdc
°C
°C
Vdc
* Forced convection—1.5 ms
–1
(300 lfm) minimum. Higher ambient temperatures are possible with increased airflow and/or decreased power
output. See the Thermal Considerations section for more details.
† The –40 °C operation is optional. See Ordering Information section.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VI = 0 to VI,max; IO = IO,max)
Inrush Transient
Input Reflected-Ripple Current
(5 Hz to 20 MHz; 500nH source impedance;See Figure 14)
Input Ripple Rejection
(100 - 120Hz)
Symbol
VI
II,max
i
2
t
Min
4.5
—
—
Typ
5.0
Max
5.5
6.1
Unit
Vdc
A
A
2
s
mAp-p
dB
—
625
60
1
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power SIP can be used in a wide variety of applications, ranging from simple stand-alone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however,
to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow
fuse with a maximum rating of 10 A (see Safety Considerations section). To aid in the proper fuse selection for the given appli-
cation, information on inrush energy and maximum dc input current is provided. Refer to the fuse manufacturer’s data for fur-
ther information.
Lineage Power