 浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第6页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第7页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第8页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第9页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第11页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第12页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第13页浏览型号MVT040A0X4-SR-P-HZ的Datasheet PDF文件第14页  
Advance Data Sheet  
November 17, 2011  
40A Analog Mega DLynxTM: Non-isolated DC-DC Power Module  
4.5 – 14.4Vdc input; 0.6Vdc to 2Vdc output; 40A output current  
Thermal Considerations  
The thermal reference points, Tref used in the  
Power modules operate in a variety of thermal  
environments; however, sufficient cooling should  
always be provided to help ensure reliable operation.  
specifications are also shown in Figure 9. For reliable  
operation the temperatures at these points should not  
exceed 120oC. The output power of the module should  
not exceed the rated power of the module (Vo,set x  
Io,max).  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel. The test set-up  
is shown in Figure 8. The preferred airflow direction  
for the module is in Figure 9.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
25.4_  
Wind Tunnel  
PWBs  
(1.0)  
Power Module  
76.2_  
(3.0)  
Figure 9. Preferred airflow direction and location of  
hot-spot of the module (Tref).  
x
Probe Location  
for measuring  
airflow and  
12.7_  
(0.50)  
ambient  
temperature  
Air  
flow  
Figure 8. Thermal Test Setup.  
LINEAGE POWER  
10