LC/LW010- and LC/LW015-Series Power Modules:  
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W  
Data Sheet  
March 27, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-  
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess  
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended  
periods can adversely affect device reliability.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Input Voltage:  
Continuous  
LC  
LW  
LW  
VI  
VI  
VI, trans  
0
0
0
50  
80  
100  
Vdc  
Vdc  
V
Transient (100 ms)  
Operating Case Temperature  
All  
TC  
–40  
105*  
°C  
(See Derating Curves, Figures 43—45.)  
Storage Temperature  
I/O Isolation  
All  
All  
Tstg  
–55  
125  
°C  
1500  
Vdc  
* Maximum case temperature varies based on power dissipation. See derating curves, Figures 43—45, for details.  
Electrical Specifications  
Table 1. Input Specifications  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
LC  
LW  
VI  
VI  
18  
36  
24  
48  
36  
75  
Vdc  
Vdc  
Maximum Input Current  
(VI = 0 to VI, max; IO = IO, max; see Figures  
1—4.)  
LC  
LW  
II, max  
II, max  
1.6  
800  
A
mA  
I2t  
II  
A2s  
Inrush Transient  
All  
All  
5
0.2  
Input Reflected-ripple Current  
mAp-p  
(5 Hz to 20 MHz; 12 µH source imped-  
ance; TA = 25 °C; see Figure 33.)  
Input Ripple Rejection (100 Hz—120 Hz)  
All  
45  
dB  
Fusing Considerations  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone  
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-  
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The  
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).  
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same  
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.  
2
Lineage Power  
 复制成功!