Data Sheet
September 9, 2008
KW0006-010 Series Power Modules:
36 – 75Vdc Input; 3.3 to 5.0Vdc Output; 6 to 10A Output Current
Isolation Specifications
Parameter
Isolation Capacitance
Isolation Resistance
I/O Isolation Voltage
Device
All
All
All
Symbol
C
iso
R
iso
All
Min
10
Typ
120
Max
1500
Unit
pF
MΩ
V
dc
General Specifications
Parameter
Calculated MTBF Based upon Telcordia SR-332
Issue 2: Method 1 Case 3, 90% confidence
(I
O
=80%I
O, max
, T
A
=40°C, Airflow = 200 lfm)
Powered Random Vibration (V
IN
=V
IN, min
, I
O
=I
O, max
,
T
A
=25°C, 0 to 5000Hz, 10Grms)
Weight
Device
F
All
All
Min
Typ
3,765,608
90
10 (0.35)
Max
Unit
Hours
Minutes
g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Remote On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
; open collector or equivalent,
Signal referenced to V
IN
(-) terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Device
Symbol
Min
Typ
Max
Unit
Logic Low - Remote On/Off Current
Logic Low - On/Off Voltage
Logic Threshold – change of state
Logic High Voltage – (Typ = Open Collector)
Logic High maximum allowable leakage current
(current flow sourced from the unit)
External voltage allowed on on/off pin
Turn-On Delay and Rise Times
(I
O
=I
O, max ,
V
IN
=V
IN, nom,
T
A
= 25 C)
Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (delay from
instant at which V
IN
= V
IN, min
until Vo=10% of Vo,set)
Case 2: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T
delay
=
from instant at which V
IN
=V
IN, min
until V
O
= 10% of V
O, set
).
Output voltage Rise time (time for Vo to rise from 10%
of V
o,set
to 90% of V
o, set
, with 0 to max ext capacitance)
Output voltage overshoot – Startup
I
O
= I
O, max
; V
IN
=V
IN, min
to V
IN, max
, T
A
= 25 C
Remote Sense Range
Output Overvoltage Protection (
requires 660 µF output
capacitance to meet limits, when Output Overvoltage is caused by
internal module failure; see Feature Descriptions for further detail
)
o
o
All
All
All
All
All
I
on/off
V
on/off
V
on/off
V
on/off
I
on/off
-0.7
3
0.37
2.4
3.4
1.0
1.2
5
10
15
mA
V
V
V
μA
V
All
T
delay
2
5
msec
All
All
T
delay
T
rise
All
2
8
5
12
3
10
msec
msec
% V
O, set
% V
O, set
V
dc
V
dc
V
dc
V
dc
V
dc
All
A
F
All
All
All
All
V
O, limit
V
O, limit
V
uv/on
V
uv/off
V
hyst
5.75
3.8
24
34
27
6
7
4.6
36
Input Undervoltage Lockout
Turn-on Threshold
Turn-off Threshold
Hysterisis
LINEAGE
POWER
4