Data Sheet  
GE  
KSTW010A0F Barracuda* Series; DC-DC Converter Power Modules  
36-75Vdc Input; 3.3Vdc, 10A Output  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.  
Parameter  
Device  
All  
Symbol  
VIN  
Min  
-0.3  
-0.3  
-40  
Max  
80  
Unit  
Vdc  
Vdc  
°C  
Input Voltage (Continuous)  
Transient (100ms)  
All  
VIN, trans  
TA  
100  
85  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
All  
All  
All  
All  
Tstg  
-55  
125  
4000  
2250  
°C  
m
Altitude*  
I/O Isolation Voltage (100% factory Hi-Pot tested)  
Vdc  
* For higher altitude applications, contact your GE Sales Representative for alternative conditions of use.  
Electrical Specifications  
Unless otherwise indicated, specifications apply at VIN = 48Vdc, resistive load, and TA = 25°C conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
All  
VIN  
36  
48  
75  
Vdc  
Input No Load Current  
All  
All  
IIN,No load  
35  
6
mA  
mA  
(VIN = 48Vdc IO = 0A, module enabled)  
Input Stand-by Current  
IIN,stand-by  
(VIN = 36 to 48Vdc, module disabled)  
Maximum Input Current (VIN=36Vdc, IO= IO,MAX  
)
All  
All  
IIN, MAX  
I2t  
1.2  
Adc  
A2s  
Inrush Transient  
0.05  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 75Vdc, IO= IOmax  
see Test configuration section)  
;
All  
All  
30  
60  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
EMC, EN55022  
See EMC Considerations section  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of  
complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety  
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 3A  
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input  
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.  
September 26, 2013  
©2013 General Electric Corporation. All rights reserved.  
Page 2  