Data Sheet  
KNW013-020 Series Power Modules:  
June 29, 2009  
36 – 75Vdc Input; 3.3 to 5.0Vdc Output; 13 to 20A Output Current  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Operating Input Voltage  
Continuous  
All  
All  
VIN  
-0.3  
-0.3  
80  
Vdc  
Vdc  
Transient (100 ms)  
VIN,trans  
100  
Operating Ambient Temperature  
(see Thermal Considerations section)  
All  
TA  
-40  
85  
°C  
Storage Temperature  
All  
All  
Tstg  
-55  
125  
°C  
I/O Isolation voltage (100% Factory Hi-Pot tested)  
2250  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
All  
VIN  
36  
48  
75  
Vdc  
Adc  
Maximum Input Current  
All  
All  
IIN,max  
1.7  
45  
2.4  
(VIN= VIN, min to VIN, max, IO=IO, max  
)
Input No Load Current  
IIN,No load  
mA  
mA  
(VIN = VIN, nom, IO = 0, module enabled)  
Input Stand-by Current  
All  
All  
IIN,stand-by  
I2t  
6
8
(VIN = VIN, nom, module disabled)  
Inrush Transient  
0.1  
A2s  
mAp-p  
dB  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 1μH source impedance; VIN, min to  
All  
All  
30  
60  
VIN, max, IO= IOmax ; See Test configuration section)  
Input Ripple Rejection (120Hz)  
EMC, EN55022  
See EMC Considerations section  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the  
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a  
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.  