欢迎访问ic37.com |
会员登录 免费注册
发布采购

JW050F1 参数 Datasheet PDF下载

JW050F1图片预览
型号: JW050F1
PDF下载: 下载PDF文件 查看货源
内容描述: DC-DC转换器; 36至75 VDC输入, 3.3 Vdc输出; 33 W至99 W¯¯ [dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 99 W]
分类和应用: 转换器DC-DC转换器
文件页数/大小: 20 页 / 838 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号JW050F1的Datasheet PDF文件第1页浏览型号JW050F1的Datasheet PDF文件第3页浏览型号JW050F1的Datasheet PDF文件第4页浏览型号JW050F1的Datasheet PDF文件第5页浏览型号JW050F1的Datasheet PDF文件第6页浏览型号JW050F1的Datasheet PDF文件第7页浏览型号JW050F1的Datasheet PDF文件第8页浏览型号JW050F1的Datasheet PDF文件第9页  
JW050F, JW075F, JW100F, JW150F Power Modules:  
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 99 W  
Data Sheet  
April 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-  
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess  
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended  
periods can adversely affect device reliability.  
Parameter  
Symbol  
Min  
Max  
Unit  
Input Voltage:  
Continuous:  
JW050F, JW075F  
JW100F, JW150F  
Transient (100 ms; JW100F, JW150F only)  
VI  
VI  
VI, trans  
75  
80  
100  
Vdc  
Vdc  
V
I/O Isolation Voltage (for 1 minute)  
1500  
100  
Vdc  
°C  
Operating Case Temperature  
TC  
–40  
(See Thermal Considerations section.)  
Storage Temperature  
Tstg  
–55  
125  
°C  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Table 1. Input Specifications  
Parameter  
Operating Input Voltage  
Symbol  
Min  
Typ  
Max  
Unit  
VI  
36  
48  
75  
Vdc  
Maximum Input Current  
(VI = 0 V to 75 V; IO = IO, max):  
JW050F (See Figure 1.)  
JW075F (See Figure 2.)  
JW100F (See Figure 3.)  
JW150F (See Figure 4.)  
II, max  
II, max  
II, max  
II, max  
1.2  
1.8  
2.4  
3.7  
A
A
A
A
Inrush Transient  
i2t  
5
1.0  
A2s  
Input Reflected-ripple Current, Peak-to-peak  
(5 Hz to 20 MHz, 12 µH source impedance;  
see Figure 17.)  
II  
mAp-p  
Input Ripple Rejection (120 Hz)  
60  
dB  
Fusing Considerations  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone  
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-  
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The  
safety agencies require a normal-blow, dc fuse with a maximum rating of 20 A (see Safety Considerations section).  
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same  
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.  
2
Lineage Power  
 复制成功!