Data Sheet  
JRW017-070 Series Power Modules DC-DC Converters  
36-75Vdc Input; 1.2Vdc to 12Vdc Output  
July 21, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
All  
Symbol  
Min  
Max  
Unit  
Input Voltage  
Continuous  
VIN  
VIN, trans  
TA  
-0.3  
-0.3  
-40  
80  
100  
85  
Vdc  
Vdc  
°C  
Transient (100 ms)  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
I/O Isolation  
All  
All  
All  
Tstg  
-55  
125  
°C  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
36  
48  
75  
Operating Input Voltage  
Maximum Input Current  
(VIN=0 to 75V , IO=IO, max  
All  
VIN  
Vdc  
Adc  
A2s  
)
All  
All  
IIN,max  
I2t  
7
1
Inrush Transient  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V  
to 75V, IO= IOmax ; see Figure 31)  
All  
All  
-
15  
60  
-
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a time-delay fuse with a maximum rating of 20A (see Safety Considerations section). Based on the  
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a  
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.  