Data Sheet  
JRW017-070 Series Power Modules DC-DC Converters  
36-75Vdc Input; 1.2Vdc to 12Vdc Output  
July 21, 2008  
Overtemperature Protection  
Feature Descriptions  
These modules feature an overtemperature protection  
circuit to safeguard against thermal damage. The  
Remote On/Off  
Two remote on/off options are available. Positive logic  
remote on/off turns the module on during a logic-high  
voltage on the ON/OFF pin, and off during a logic low.  
Negative logic remote on/off turns the module off  
during a logic high and on during a logic low. Negative  
logic, device code suffix "1," is the factory-preferred  
configuration. To turn the power module on and off,  
the user must supply a switch to control the voltage  
between the on/off terminal and the VI (-) terminal  
(Von/off). The switch can be an open collector or  
equivalent (see Figure 46). A logic low is Von/off = 0  
V to I.2 V. The maximum Ion/off during a logic low is 1  
mA. The switch should maintain a logic-low voltage  
while sinking 1 mA. During a logic high, the maximum  
Von/off generated by the power module is 15 V. The  
maximum allowable leakage current of the switch at  
Von/off = 15V is 50 µA. If not using the remote on/off  
feature, perform one of the following to turn the unit  
on:  
circuit shuts down and latches off the module when  
the maximum device reference temperature is  
exceeded. The module can be restarted by cycling  
the dc input power for at least one second or by  
toggling the remote on/off signal for at least one  
second.  
Over Voltage Protection  
The output overvoltage protection consists of circuitry  
that monitors the voltage on the output terminals. If  
the voltage on the output terminals exceeds the over  
voltage protection threshold, then the module will  
shutdown and latch off. The overvoltage latch is reset  
by either cycling the input power for one second or by  
toggling the on/off signal for one second. The  
protection mechanism is such that the unit can  
continue in this condition until the fault is cleared.  
For negative logic, short ON/OFF pin to VI(-).  
For positive logic: leave ON/OFF pin open.  
Remote sense  
Remote sense minimizes the effects of distribution  
losses by regulating the voltage at the remote-sense  
connections. The voltage between the remote-sense  
pins and the output terminals must not exceed the  
output voltage sense range given in the Feature  
Specifications table i.e.:  
[Vo(+) – Vo(-)] – [SENSE(+) – SENSE(-)] 10% of  
Vo,nom  
.
The voltage between the Vo(+) and Vo(-) terminals  
must not exceed the minimum output overvoltage  
shut-down value indicated in the Feature  
Specifications table. This limit includes any increase  
in voltage due to remote-sense compensation and  
output voltage set-point adjustment (trim). See Figure  
47. If not using the remote-sense feature to regulate  
the output at the point of load, then connect  
SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the  
module.  
Although the output voltage can be increased by both  
the remote sense and by the trim, the maximum  
increase for the output voltage is not the sum of both.  
The maximum increase is the larger of either the  
remote sense or the trim. The amount of power  
delivered by the module is defined as the voltage at  
the output terminals multiplied by the output current.  
When using remote sense and trim: the output  
voltage of the module can be increased, which at the  
same output current would increase the power output  
of the module. Care should be taken to ensure that  
the maximum output power of the module remains at  
or below the maximum rated power.  
Figure 46. Remote On/Off Implementation.  
Overcurrent Protection  
To provide protection in a fault output overload  
condition, the module is equipped with internal  
current-limiting circuitry and can endure current limit  
for few seconds. If overcurrent persists for few  
seconds, the module will shut down and remain latch-  
off. The overcurrent latch is reset by either cycling the  
input power or by toggling the on/off pin for one  
second. If the output overload condition still exists  
when the module restarts, it will shut down again. This  
operation will continue indefinitely until the  
overcurrent condition is corrected.  
An auto-restart option is also available.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module  
will begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
LINEAGE POWER  
15  