 浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第5页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第6页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第7页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第8页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第10页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第11页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第12页浏览型号JRCK017A0S32R06435Z的Datasheet PDF文件第13页  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
the voltage step and range of the DAC and the desired values  
Feature Description (continued)  
for trim-up and trim-down %. Please contact your GE  
technical representative to obtain more details on the  
selection for this resistor.  
Figure 14. Circuit Configuration to Increase Output Voltage.  
The voltage between the Vo(+) and Vo(-) terminals must not  
exceed the minimum output overvoltage shut-down value  
indicated in the Feature Specifications table. This limit  
includes any increase in voltage due to remote- sense  
compensation and output voltage set-point adjustment (trim).  
See Figure 11.  
Figure 15. Circuit Configuration to Actively Adjust the  
Output Voltage.  
AC+DC Load Capability  
The JRCK017S32R0x is compatible with load profiles as shown  
in Figure 16.  
Although the output voltage can be increased by both the  
remote sense and by the trim, the maximum increase for the  
output voltage is not the sum of both. The maximum increase  
is the larger of either the remote sense or the trim. The  
amount of power delivered by the module is defined as the  
voltage at the output terminals multiplied by the output  
current. When using remote sense and trim, the output  
voltage of the module can be increased, which the same  
output current would increase the power output of the  
module. Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
Examples:  
To trim down the output of a nominal 32V module, without –T  
option, to 16.8V  
28 16.8  
%   
100 40%  
28  
100  
Radj _ down  
2 0.5k  
40  
To trim up the output of a nominal 32V module, without –T  
option, to 30.8V  
Figure 16. AC-DC Load Profile  
30.828  
The output voltage peak deviation shall not exceed the peak  
values listed in the Electrical Specifications Table.  
%   
100 10.0%  
28  
28 (100 10 ) (100 (2 10 )  
Tunable Loop  
R
adj _ up  
1.225 10  
10  
The JRCK017S32R0x-T modules have a new feature that  
optimizes transient response of the module called Tunable  
Loop.  
R
adj_up = 239k  
Active Voltage Programming  
External capacitors are usually added to the output of the  
module for two reasons: to reduce output ripple and noise  
and to reduce output voltage deviations from the steady-  
state value in the presence of dynamic load current changes.  
For both the JRCK017S32R0x and JRCK017S32R0x-T, a  
Digital-Analog converter (DAC), capable of both sourcing and  
sinking current, can be used to actively set the output voltage,  
as shown in Figure 15. The value of RG will be dependent on  
Adding external capacitance however affects the voltage  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 9  