JPW200S52R5-BH Power Module; dc-dc Converter
38 Vdc - 75 Vdc Input, 52.5 Vdc Output; 200W
Data Sheet
March 26, 2008
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Parameter
Input Voltage:Continuous
Device
All
Symbol
VI
Min
—
Max
75
Unit
Vdc
°C
Operating Ambient Temperature
All
TA
–40
85
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage
All
—
Tstg
—
–55
—
125
°C
2250
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
VIN
38
52
75
Vdc
Under Voltage Lock-out
turn on
turn off
—
—
VITON
VITOFF
36.5
34.6
37.9
36
Vdc
Vdc
Maximum Input Current
—
—
7.0
Adc
(VI = 0 V to 75 V; IO = IO, max)
Inrush Transient
I2t
2
A2s
mA
Input Current @ No Output Load
(VI = 52 Vdc; Io = 0A; TA = 25° C; on/off pin enabled
Iin, no load
—
—
140
5
—
Input Reflected Ripple Current, peak-peak
(5 Hz to 20 MHz, 12 µH source impedance
See Test configuration section)
—
mAp-p
dB
Input Ripple Rejection (120 Hz)@Vin=52V
34
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated
part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a
maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s