Data Sheet  
JNW350R Power Modules; DC-DC Converters  
36 – 75 Vdc Input; 28Vdc Output; 350W Output  
July 27, 2009  
Test Configurations  
Design Considerations  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance source. A highly inductive source  
impedance can affect the stability of the power  
module. For the test configuration in Figure 7, a  
470μF Low ESR aluminum capacitor, CIN , mounted  
close to the power module helps ensure the stability  
of the unit. Consult the factory for further application  
guidelines  
Output Capacitance  
Note: Measure the input reflected-ripple current with a  
simulated source inductance (LTEST) of 12 µH. Capacitor  
CS offsets possible battery impedance. Measure the current,  
as shown above.  
Figure 7. Input Reflected Ripple Current Test  
Setup.  
The JNW350R power module requires a minimum  
output capacitance of 440µF Low ESR aluminum  
capacitor, Cout to ensure stable operation over the full  
range of load and line conditions, see Figure 8. If the  
ambient temperature is under -20C, it is required to  
use at least 3 pcs of minimum capacitors in parallel.  
In general, the process of determining the acceptable  
values of output capacitance and ESR is complex and  
is load-dependant.  
Safety Considerations  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standard, i.e., UL60950-1, CSA C22.2 No. 60950-1-  
03, EN60950-1 and VDE 0805:2001-12.  
Note: Use a Cout (470 µF Low ESR aluminum or tantalum  
capacitor typical), a 0.1 µF ceramic capacitor and a 10 µF  
ceramic capacitor, and Scope measurement should be made  
using a BNC socket. Position the load between 51 mm and  
76 mm (2 in. and 3 in.) from the module.  
For end products connected to –48V dc, or –60Vdc  
nominal DC MAINS (i.e. central office dc battery  
plant), no further fault testing is required. *Note: -60V  
dc nominal battery plants are not available in the U.S.  
or Canada.  
Figure 8. Output Ripple and Noise Test Setup.  
For all input voltages, other than DC MAINS, where  
the input voltage is less than 60V dc, if the input  
meets all of the requirements for SELV, then:  
ƒ
The output may be considered SELV. Output  
voltages will remain within SELV limits even with  
internally-generated non-SELV voltages. Single  
component failure and fault tests were performed  
in the power converters.  
Note: All measurements are taken at the module terminals.  
When socketing, place Kelvin connections at module  
terminals to avoid measurement errors due to socket contact  
resistance.  
ƒ
One pole of the input and one pole of the output  
are to be grounded, or both circuits are to be kept  
floating, to maintain the output voltage to ground  
voltage within ELV or SELV limits. However,  
SELV will not be maintained if VI(+) and VO(+)  
are grounded simultaneously.  
Figure 9. Output Voltage and Efficiency Test  
Setup.  
LINEAGE POWER  
6
 复制成功!