Data Sheet  
JNW350R Power Modules; DC-DC Converters  
36 – 75 Vdc Input; 28Vdc Output; 350W Output  
July 27, 2009  
R
TUNE and CTUNE for different values of ceramic output  
conduction, convection, and radiation to the  
surrounding environment. Proper cooling can be  
verified by measuring the case temperature. Peak  
temperature (TREF) occurs at the position indicated in  
Figure 15.  
capacitors up to 8000μF that might be needed for an  
application to meet output ripple and noise  
requirements. Selecting RTUNE and CTUNE according to  
Table 2 will ensure stable operation of the module  
In applications with tight output voltage limits in the  
presence of dynamic current loading, additional  
output capacitance will be required. Table 2 lists  
recommended values of RTUNE and CTUNE in order to  
meet 2% output voltage deviation limits for some  
common output voltages in the presence of a 6A to  
12A step change (50% of full load), with an input  
voltage of 48V.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
For reliable operation this temperature should not  
exceed 100ºC at TREF 1 for cold plate applications or  
exceed 112ºC at TREF 2 for applications using forced  
convection airflow. The output power of the module  
should not exceed the rated power for the module as  
listed in the ordering Information table. Although the  
maximum TREF temperature of the power modules is  
discussed above, you can limit this temperature to a  
lower value for extremely high reliability.  
Table 1. General recommended values of of RTUNE  
and CTUNE for Vout=28V and various external  
ceramic capacitor combinations.  
Cout(µF)  
RTUNE(kΩ)  
CTUNE(pF)  
1100  
348  
2200  
200  
4400  
6600  
8000  
51.1  
36.5  
40.2  
1500  
6800  
10,000 15,000 15,000  
Table 2. Recommended values of RTUNE and CTUNE  
to obtain transient deviation of 2% of Vout for a  
6A step load with Vin=48V.  
Vo  
Co(uF)  
RTUNE(kΩ)  
32V  
880  
1000  
28V  
880  
402  
25V  
1100 1320 1320 1540  
348 221 84.5 61.9  
22V  
19V 16.8V  
CTUNE(pF) 820  
1500 1500 2200 3300 6800  
500 530 420 370 317  
530  
ΔV  
Please contact your Lineage Power technical  
representative to obtain more details of this feature as  
well as for guidelines on how to select the right value  
of external R-C to tune the module for best transient  
performance and stable operation for other output  
capacitance values.  
Over Temperature Protection  
Figure 19. Case (TREF ) Temperature Measurement  
Location (top view).  
The JNW350R module provides with non-latching  
over temperature protection. A temperature sensor  
monitors the operating temperature of the converter. If  
the reference temperature exceeds a threshold of 110  
ºC (typical) at the center of the baseplate, the  
converter will shut down and disable the output. When  
the baseplate temperature has decreased by  
approximately 20 ºC the converter will automatically  
restart.  
Thermal Derating  
Thermal derating is presented for two different  
applications: 1) Figure 20, the JNW350R module is  
thermally coupled to a cold plate inside a sealed  
clamshell chassis, without any internal air circulation;  
and 2) Figure 21 and 22, the JNW350R module is  
mounted in a traditional open chassis or cards with  
forced air flow. In application 1, the module is cooled  
entirely by conduction of heat from the module  
primarily through the top surface to a coldplate, with  
some conduction through the module’s pins to the  
power layers in the system board. For application 2,  
the module is cooled by heat removal into a forced  
airflow that passes through the interior of the module  
and over the top baseplate and/or attached heatsink.  
The module can be restarted by cycling the dc input  
power for at least one second or by toggling the  
remote on/off signal for at least one second.  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation of the unit.  
Heat-dissipating components inside the unit are  
thermally coupled to the case. Heat is removed by  
LINEAGE POWER  
11