 浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第1页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第3页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第4页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第5页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第6页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第7页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第8页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第9页  
JHW250S30R2 Power Module; dc-dc Converter
36 – 75 Vdc Input; 30.2Vdc Output; 250W
Data Sheet
October 6, 2005
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient (100ms)
Operating Ambient Temperature (Case)
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage
JHW
JHW
All
All
All
V
IN
V
IN, trans
T
c
T
stg
-0.3
-0.3
-40
-55
80
100
100
125
1500
Vdc
Vdc
°C
°C
Vdc
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=0V to 36V, I
O
=I
O, max
)/(V
IN
=0V to 75V, I
O
=I
O, max
)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V
IN
=0V to
75V, I
O
= I
Omax
; see Figure 13)
Input Ripple Rejection (120Hz)
Device
JHW
JHW
All
All
Symbol
V
IN
I
IN,max
It
2
Min
36
Typ
48
Max
75
9.0
2
Unit
Vdc
Adc
As
mAp-p
2
7
15
All
60
dB
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 15A for JHW250 series (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type
of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
2
Tyco Electronics Power Systems.