 浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第6页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第7页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第8页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第9页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第11页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第12页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第13页浏览型号JHW250S30R21-18TZ的Datasheet PDF文件第14页  
JHW250S30R2 Power Module; dc-dc Converter  
36 – 75 Vdc Input; 30.2Vdc Output; 250W  
Data Sheet  
October 6, 2005  
Trim Examples:  
To trim down the output of a nominal 30.2V module  
(JHW250S30R2) to 28.0V  
[(  
2× 28  
)
30.2  
]
KΩ  
Radj down = 10×  
(
30.2 28  
)
Radj-down = 117.27 KΩ  
To trim up the output of a nominal 30.2V module  
(JHW250S30R2) to 31.0V  
31.0  
0.04056×31.0 1.225  
R
adj up = 9.5944×⎜  
⎟ −10 KΩ  
(
)
Rtadj-up = 9181 KΩ  
Output Overvoltage Protection - Latching  
The output overvoltage protection consists of circuitry  
that monitors the voltage on the output terminals. If the  
voltage on the output terminals exceeds the over voltage  
protection threshold, then the module will shutdown and  
latch off. The latch is reset by either cycling the input  
power for one second or by toggling the on/off signal for  
one second. The protection mechanism is such that the  
unit can continue in this condition until the fault is  
cleared.  
Overtemperature Protection - Latching  
These modules feature an overtemperature protection  
circuit to safeguard against thermal damage. The circuit  
shuts down and latches off the module when the  
maximum baseplate reference temperature is exceeded.  
The latch is reset by either cycling the input power for  
one second or by toggling the on/off signal for one  
second. The protection mechanism is such that the unit  
can continue in this condition until the fault is cleared.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module will  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
10  
Tyco Electronics Power Systems