欢迎访问ic37.com |
会员登录 免费注册
发布采购

JBW030F 参数 Datasheet PDF下载

JBW030F图片预览
型号: JBW030F
PDF下载: 下载PDF文件 查看货源
内容描述: 36-75 VDC输入; 3.3伏和5伏直流输出; 30瓦 [36-75 Vdc Input; 3.3 Vdc and 5 Vdc Outputs; 30 W]
分类和应用:
文件页数/大小: 16 页 / 295 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号JBW030F的Datasheet PDF文件第4页浏览型号JBW030F的Datasheet PDF文件第5页浏览型号JBW030F的Datasheet PDF文件第6页浏览型号JBW030F的Datasheet PDF文件第7页浏览型号JBW030F的Datasheet PDF文件第9页浏览型号JBW030F的Datasheet PDF文件第10页浏览型号JBW030F的Datasheet PDF文件第11页浏览型号JBW030F的Datasheet PDF文件第12页  
JBW030-Series Power Module: dc-dc Converters  
36-75 Vdc Input; 3.3 Vdc and 5 Vdc Outputs; 30 W  
Data Sheet  
March 27, 2008  
Design Considerations  
Grounding Considerations  
Feature Descriptions  
Overcurrent Protection  
To provide protection in a fault (output overload) condi-  
tion, the unit is equipped with internal current-limiting  
circuitry and can endure current limiting for an unlim-  
ited duration. At the point of current-limit inception, the  
unit shifts from voltage control to current control. If the  
output voltage is pulled very low during a severe fault,  
the current-limit circuit can exhibit either foldback or  
tailout characteristics (output current decrease or  
increase). The unit operates normally once the output  
current is brought back into its specified range.  
The case is not connected internally to allow the user  
flexibility in grounding.  
Input Source Impedance  
The power module should be connected to a low ac-  
impedance input source. Highly inductive source  
impedances can affect the stability of the power mod-  
ule. A 33 µF electrolytic capacitor (ESR < 0.7 Ω at  
100 kHz) mounted close to the power module helps  
ensure stability of the unit. (See Figure 11.)  
Remote On/Off  
Two remote on/off options are available. Positive logic  
remote on/off turns the module on during a logic-high  
voltage on the REMOTE ON/OFF pin, and off during a  
logic low. Negative logic remote on/off turns the module  
off during a logic high and on during a logic low. Nega-  
tive logic, device code suffix “1,” is the factory-preferred  
configuration.  
Safety Considerations  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standard,  
i.e., UL 60950, CSA C22.2 No. 60950-00, and EN  
60950 (VDE0805):2001-12.  
To turn the power module on and off, the user must  
supply a switch to control the voltage between the  
on/off terminal and the VI(–) terminal (Von/off). The  
switch can be an open collector or equivalent (see Fig-  
ure 14). A logic low is Von/off = –0.7 V to 1.2 V, during  
which the module is off. The maximum Ion/off during a  
logic low is 1 mA. The switch should maintain a logic-  
low voltage while sinking 1 mA.  
If the input source is non-SELV (ELV or a hazardous  
voltage greater than 60 Vdc and less than or equal to  
75 Vdc), for the module's output to be considered  
meeting the requirements of safety extra-low voltage  
(SELV), all of the following must be true:  
n The input source is to be provided with reinforced  
insulation from any other hazardous voltages, includ-  
ing the ac mains.  
During a logic high, the maximum Von/off generated by  
the power module is 15 V. The maximum allowable  
leakage current of the switch at Von/off = 15 V is 50 µA.  
n One VI pin and one VO pin are to be grounded or  
both the input and output pins are to be kept floating.  
The module has internal capacitance to reduce noise  
at the ON/OFF pin. Additional capacitance is not gen-  
erally needed and may degrade the start-up character-  
istics of the module.  
n The input pins of the module are not operator acces-  
sible.  
n Another SELV reliability test is conducted on the  
whole system, as required by the safety agencies, on  
the combination of supply source and the subject  
module to verify that under a single fault, hazardous  
voltages do not appear at the module's output.  
CAUTION: To avoid damaging the power module  
or external on/off circuit, the connec-  
tion between the VI(–) pin and the input  
source must be made before or simulta-  
neously to making a connection  
Note: Do not ground either of the input pins of the  
module without grounding one of the output  
pins. This may allow a non-SELV voltage to  
appear between the output pins and ground.  
between the ON/OFF pin and the input  
source (either directly or through the  
external on/off circuit.)  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
The input to these units is to be provided with a maxi-  
mum 5 A fast-acting fuse in the ungrounded lead.  
8
Lineage Power  
 复制成功!