HW006/010/012 Series Power Modules; dc-dc Converters  
36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A  
Data Sheet  
June 26, 2009  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress  
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the  
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the  
device reliabiltiy.  
Parameter  
Input Voltage:Continuous  
Device  
Symbol  
Min  
Max  
Unit  
HW  
HW  
VI  
VI, trans  
–0.3  
80  
100  
Vdc  
Vdc  
Transient (100ms)  
Operating Ambient Temperature  
All  
TA  
–40  
85  
°C  
(See Thermal Considerations section)  
Storage Temperature  
All  
Tstg  
–55  
125  
°C  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.  
Parameter  
Device  
HW  
Symbol  
VIN  
Min  
Typ  
Max  
75  
Unit  
Vdc  
Adc  
Operating Input Voltage  
Maximum Input Current  
(VI = 0 V to 75 V; IO = IO, max)  
36  
48  
HW  
II, max  
1.6  
Inrush Transient  
All  
All  
I2t  
II  
1
A2s  
Input Reflected Ripple Current, peak-peak  
(5 Hz to 20 MHz, 12 µH source impedance  
See Test configuration section)  
3
mAp-p  
Input Ripple Rejection (120 Hz)  
All  
50  
dB  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated  
part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve  
maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a  
maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush  
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s  
data sheet for further information.  