欢迎访问ic37.com |
会员登录 免费注册
发布采购

HW004A0A1Z 参数 Datasheet PDF下载

HW004A0A1Z图片预览
型号: HW004A0A1Z
PDF下载: 下载PDF文件 查看货源
内容描述: 18-36VDC和36-75VDC输入; 1.0V - 5V直流输出; 4A - 6A的输出电流 [18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current]
分类和应用:
文件页数/大小: 28 页 / 641 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号HW004A0A1Z的Datasheet PDF文件第1页浏览型号HW004A0A1Z的Datasheet PDF文件第3页浏览型号HW004A0A1Z的Datasheet PDF文件第4页浏览型号HW004A0A1Z的Datasheet PDF文件第5页浏览型号HW004A0A1Z的Datasheet PDF文件第6页浏览型号HW004A0A1Z的Datasheet PDF文件第7页浏览型号HW004A0A1Z的Datasheet PDF文件第8页浏览型号HW004A0A1Z的Datasheet PDF文件第9页  
Data Sheet
May 16, 2008
HW/HC004/005/006 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient (100ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory tested)
All
All
T
stg
-55
125
2250
°C
Vdc
Device
HC
HW
HW
All
Symbol
V
IN
V
IN
V
IN, trans
T
A
Min
-0.3
-0.3
-0.3
-40
Max
50
80
100
85
Unit
Vdc
Vdc
Vdc
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=0V to 75V, I
O
=I
O, max
)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V
IN
=0V to
75V, I
O
= I
Omax
; see Figure 9)
Input Ripple Rejection (120Hz)
EMC, EN55022
Device
HC
HW
HC
HW
All
All
All
Symbol
V
IN
V
IN
I
IN,max
I
IN,max
It
5
50
See EMC Considerations section
2
Min
18
36
Typ
24
54
Max
36
75
1.75
0.85
1
Unit
Vdc
Vdc
Adc
Adc
As
mAp-p
dB
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2