Data Sheet  
HW/HC004/005/006 Series DC-DC Power Module:  
May 16, 2008  
18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current  
only begin to operate once the input voltage is raised  
Feature Description  
above the undervoltage lockout turn-on threshold,  
VUV/ON  
Remote On/Off  
.
Once operating, the module will continue to operate until  
the input voltage is taken below the undervoltage turn-off  
Two remote on/off options are available. Positive logic  
turns the module on during a logic high voltage on the  
ON/OFF pin, and off during a logic low. Negative logic  
remote On/Off, device code suffix “1”, turns the module  
off during a logic high and on during a logic low.  
threshold, VUV/OFF  
.
Over Voltage Protection  
The output overvoltage protection consists of circuitry  
that internally clamps the output voltage. If a more  
accurate output overvoltage protection scheme is  
required then this should be implemented externally via  
use of the remote on/off pin.  
To maintain compatibility with LW series power modules  
the Remote On/Off pin is optional for the TH (through  
hole) version. Standard TH modules have no On/Off pin  
fitted. TH modules ordered with device code suffix “1”  
are negative logic with the On/Off pin fitted.  
Over Temperature Protection  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shutdown if the overtemperature threshold of 125 oC is  
exceeded at the thermal reference point Tref . Once the  
unit goes into thermal shutdown it will then wait to cool  
before attempting to restart.  
VIN(+)  
VO  
Ion/off  
ON/OFF  
Von/off  
Output Voltage Programming  
COM  
Trimming allows the output voltage set point to be  
increased or decreased, this is accomplished by  
connecting an external resistor between the TRIM pin  
and either the VO(+) pin or the VO(-) pin (COM pin) .  
VIN(-)  
VIN(+)  
VO(+)  
VOTRIM  
COM  
Figure 64. Remote On/Off Implementation.  
Rtrim-up  
To turn the power module on and off, the user must  
supply a switch (open collector or equivalent) to control  
the voltage (Von/off) between the ON/OFF terminal and  
the VIN(-) terminal. Logic low is 0V Von/off 1.2V. The  
maximum Ion/off during a logic low is 1mA, the switch  
should be maintain a logic low level whilst sinking this  
current.  
ON/OFF  
LOAD  
Rtrim-down  
VIN(-)  
During a logic high, the typical Von/off generated by the  
module is 5.8V, and the maximum allowable leakage  
current at Von/off = 5.8V is 10μA.  
Figure 65. Circuit Configuration to Trim Output  
Voltage.  
If not using the remote on/off feature:  
For positive logic, leave the ON/OFF pin open.  
For negative logic, short the ON/OFF pin to VIN(-).  
Overcurrent Protection  
Connecting an external resistor (Rtrim-down) between the  
TRIM pin and the COM pin decreases the output voltage  
set point. To maintain set point accuracy, the trim  
resistor tolerance should be ±0.1%.  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally  
once the output current is brought back into its specified  
range. The average output current during hiccup is 10%  
IO, max  
.
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module will  
LINEAGE POWER  
17