 浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第4页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第5页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第6页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第7页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第9页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第10页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第11页浏览型号GDX040A0X4-SR-P-HZ的Datasheet PDF文件第12页  
Advance Data Sheet  
November 17, 2011  
40A Analog Mega DLynxTM: Non-isolated DC-DC Power Module  
4.5 – 14.4Vdc input; 0.6Vdc to 2Vdc output; 40A output current  
connected across the sequencing voltage before it is  
fed to the SEQ pin as shown in Fig. 5.  
module as shown in Fig. 6, with the converter being  
synchronized by the rising edge of the external signal.  
The Electrical Specifications table specifies the  
requirements of the external SYNC signal. If the SYNC  
pin is not used, the module should free run at the  
default switching frequency. If synchronization is not  
being used, connect the SYNC pin to GND.  
DLynx Module  
V
SEQ  
20K  
SEQ  
MODULE  
R1=Rtrim  
SYNC  
SIG_GND  
100 pF  
+
GND  
Figure 5. Circuit showing connection of the  
sequencing signal to the SEQ pin.  
Figure 6. External source connections to  
synchronize switching frequency of the module.  
When the scaled down sequencing voltage is applied  
to the SEQ pin, the output voltage tracks this voltage  
until the output reaches the set-point voltage. The final  
value of the sequencing voltage must be set higher  
than the set-point voltage of the module. The output  
voltage follows the sequencing voltage on a one-to-  
one basis. By connecting multiple modules together,  
multiple modules can track their output voltages to the  
voltage applied on the SEQ pin.  
Dual Layout  
Identical dimensions and pin layout of Analog and  
Digital Mega DLynx modules permit migration from  
one to the other without needing to change the layout.  
In both cases the trim resistor is connected between  
trim and signal ground.  
To initiate simultaneous shutdown of the modules, the  
SEQ pin voltage is lowered in a controlled manner.  
The output voltage of the modules tracks the voltages  
below their set-point voltages on a one-to-one basis.  
A valid input voltage must be maintained until the  
tracking and output voltages reach ground potential.  
Power Good  
The module provides a Power Good (PGOOD) signal  
that is implemented with an open-drain output to  
indicate that the output voltage is within the regulation  
limits of the power module. The PGOOD signal will be  
de-asserted to a low state if any condition such as  
overtemperature, overcurrent or loss of regulation  
occurs that would result in the output voltage going  
±10% outside the setpoint value. The PGOOD terminal  
can be connected through a pullup resistor (suggested  
value 100KΩ) to a source of 5VDC or lower.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally  
once the output current is brought back into its  
specified range.  
Tunable LoopTM  
Overtemperature Protection  
The module has a feature that optimizes transient  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shut down if the overtemperature threshold of  
response of the module called Tunable LoopTM  
.
External capacitors are usually added to the output of  
the module for two reasons: to reduce output ripple  
and noise and to reduce output voltage deviations from  
the steady-state value in the presence of dynamic load  
current changes. Adding external capacitance however  
affects the voltage control loop of the module, typically  
causing the loop to slow down with sluggish response.  
Larger values of external capacitance could also cause  
the module to become unstable.  
The Tunable LoopTM allows the user to externally  
adjust the voltage control loop to match the filter  
network connected to the output of the module. The  
Tunable LoopTM is implemented by connecting a series  
R-C between the VS+ and TRIM pins of the module,  
as shown in Fig. 7. This R-C allows the user to  
TBDoC(typ) is exceeded at the thermal reference point  
T
ref .Once the unit goes into thermal shutdown it will  
then wait to cool before attempting to restart.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module  
will begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
Synchronization  
The module switching frequency can be synchronized  
to a signal with an external frequency within a  
specified range. Synchronization can be done by using  
the external signal applied to the SYNC pin of the  
LINEAGE POWER  
8
 复制成功!