FLTR75V05 Filter Module  
75 Vdc Input Maximum, 5 A Maximum  
Data Sheet  
October 2009  
Application (continued)  
Other Considerations  
Figures 9, 10 & 11 show some experimental results for  
It is essential for good EMI performance that the input  
various Lineage Power modules obtained by using the fil- lines not be contaminated with noise after passing  
ter module, together with the recommended external  
components shown in Figures 5 and 6. Measured  
noise is highly dependent on layout, grounding, cable  
orientation, and load characteristics and will, vary from  
application to application.  
through the filter. Filtered input traces should therefore  
be kept away from noise sources such as power mod-  
ules and switching logic lines. If input voltage sense  
traces must be routed past the power modules from the  
quiet side of the filter module, they should be filtered at  
the point where they leave the quiet input lines. Input  
traces should be kept as far away from output power  
traces as possible.  
Thermal Considerations  
The fundamental switching frequency noise spike can  
be somewhat reduced by adding a high-frequency  
capacitor of a few microfarads across the input lines of  
the filter module.  
The case temperature must be kept below 100 °C. The  
case temperature (TC) should be measured at the posi-  
tion indicated in Figure 8. Therefore, for a particular  
current and ambient temperature, the airflow at the fil-  
ter must be adequate.  
Adding additional components to the input filter to  
improve performance usually has very limited payback,  
and may actually increase the noise conducted onto  
the input lines. Adding Y caps to the input side of the fil-  
ter module couples any noise in the ground plane  
directly into the input lines, usually degrading perfor-  
mance. Adding additional X and Y caps to the power  
module side of the filter module produces low-  
impedance loops for high-frequency currents to flow,  
possibly degrading performance.  
Example:  
Given: IO, max = 4 A; TA, max = 95 °C  
Therefore ΔT, max allowable = 5 °C  
Determine airflow required (Figure 1): v = 2.0 m/s  
(400lfm)  
MEASURE CASE  
TEMPERATURE HERE  
VI(-)  
GND  
VO(-)  
Adding additional common-mode or differential-mode  
filtering to the power module output leads decreases  
the power module output noise, and also frequently  
reduces the input noise by decreasing the noise cou-  
pled from output leads to input leads. Common-mode  
output filtering is particularly important if the load is tied  
to chassis ground. If common-mode filtering is added  
to the power module output, ensure that remote-sense  
leads sense the output voltage before the common-  
mode filter. Do not use remote-sense on the load side  
of an output common-mode filter.  
12.7  
(0.5)  
VI(+)  
VO(+)  
6.1  
(0.24)  
1-0146  
Note: Top view, pin locations are for reference only. Measurements  
are shown in millimeters and (inches).  
If input noise performance is unsatisfactory after apply-  
ing the filter module as described previously, the best  
remedy is to modify the layout and grounding scheme.  
It is often useful to make a model of the power card,  
using copper tape and a vector card, to experiment  
with various layout and grounding approaches prior to  
committing to a printed-wiring board.  
Figure 8. Case Temperature Measurement  
Location  
8
Lineage Power  