Data Sheet
March 2008
FLTR100V10 Filter Module
75 Vdc Input Maximum, 10 A Maximum
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage and temperature conditions.
Parameter
Resistance per Leg
Maximum Average Current
(T
A
= 60 °C, 2.03 m/s (400 lfm) air)
Maximum Average Current
(T
A
= 60 °C, natural convection)
Common-mode Insertion Loss
(50
Ω
circuit, 500 kHz)
Differential-mode Insertion Loss
(50
Ω
circuit, 500 kHz)
Symbol
R
I
max
I
max
—
—
Min
—
—
—
—
—
Typ
—
—
—
36
44
Max
14
10
6.5
—
—
Unit
mΩ
A
A
dB
dB
Characteristics
0
COMMON-MODE INSERTION LOSS (dB)
12
10
8
6
4
2
0
20
400 LFM
-20
-40
-60
NC
200 LFM
-80
30
40
50
60
70
80
90
-100
0.1
1.0
FREQUENCY (MHz)
10
8-1326b
Figure 1. Derating output current vs. Local
ambient temperature and Airflow (Vin =
48Vdc)
Figure 2. Typical Common-Mode Insertion Loss in
a 50
Ω
Circuit
Lineage Power
3