Data Sheet
March 26, 2008
FLT007A0/FLT007A0-SR Input Filter Modules
75Vdc Input Voltage Maximum, 7A Output Current Maximum
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O to Ground Isolation
All
All
T
stg
−
-55
−
125
2250
°C
Vdc
All
All
V
IN
T
A
0
-40
100
85
Vdc
°C
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input-to-Output Current
(V
IN
= 0 to V
iN,max
)
Resistance per leg
All
All
I
max
R
7
25
Adc
mΩ
Device
All
Symbol
V
IN
Min
0
Typ
24/48
Max
75
Unit
Vdc
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 10 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2