Data Sheet  
EUK240 Series Power Modules; DC-DC converters  
36 – 60Vdc input; 9.6Vdc Output; 240W  
March 26, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute  
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those  
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can  
adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
Continuous  
All  
All  
All  
All  
All  
VIN  
-0.3  
-0.3  
-40  
-55  
60  
75  
Vdc  
Vdc  
°C  
Non-Operating Condition  
Operating Ambient Temperature  
Storage Temperature  
I/O Isolation Voltage (100% factory tested)  
TA  
85  
Tstg  
Viso  
125  
1500  
°C  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
Maximum Input Current  
(VIN=0 to 60Vdc, PO=PO, max  
All  
VIN  
36  
48  
60  
Vdc  
Adc  
A2s  
)
All  
All  
IIN,max  
I2t  
5
1
Inrush Transient  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance;  
Ta 25oC, Cin = 33 µF)  
All  
All  
50  
14  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being  
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to  
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-  
acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in  
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be  
used. Refer to the fuse manufacturer’s data sheet for further information.  