Data Sheet
ESTW025A0F Series Eighth-Brick Power Modules
36–75Vdc Input; 3.3Vdc Output; 25A Output
October 11, 2011
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Output
Voltage Current
Output
On/Off
Logic
Connector
Type
Product Codes
Input Voltage
Comcodes
ESTW025A0F41Z
ESTW025A0F41-HZ
ESTW025A0F41-SZ
ESTW025A0F641
ESTW025A0F4Z
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
48V (36-75Vdc)
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
25A
25A
25A
25A
25A
25A
25A
25A
Negative
Negative
Negative
Negative
Positive
Negative
Negative
Positive
Through hole
Through hole
Surface Mount
Through hole
Through hole
Through hole
Through hole
Through hole
CC109158498
CC109159505
CC109159496
CC109159125
CC109168118
CC109169363
ESTW025A0F641Z
ESTW025A0F841Z
CC109167367
CC109172846
ESTW025A0F64-18HZ 48V (36-75Vdc)
Table 2. Device Options
Character and Position
Characteristic
Form Factor
Definition
E = Eighth Brick
E
Family Designator
Input Voltage
ST
ST = Stingray Series
W = Wide Range, 36V-75V
W
Output Current
Output Voltage
025A0
025A0 = 025.0 Amps Maximum Output Current
F = 3.3V nominal
F
Omit = Default Pin Length shown in Mechanical Outline Figures
6 = Pin Length: 3.68 mm ± 0.25mm , (0.145 in. ± 0.010 in.)
8 = Pin Length: 2.79 mm ± 0.25mm , (0.110 in. ± 0.010 in.)
Omit = Latching Mode
4 = Auto-restart following shutdown (Overcurrent/Overvoltage)
Omit = Positive Logic
Pin Length
6
8
Action following
Protective
4
On/Off Logic
1
1 = Negative Logic
Customer Specific
XY = Customer Specific Modified Code, Omit for Standard Code
XY
Omit = Standard open Frame Module
H = 1/8th Brick size heat plate, for
use with heat sinks (not available with –S option)
H
Mechanical Features
18H = 1/4th Brick size heat plate with unthreaded inserts for
use in coldwall applications (not available with –S option)
18H
S = Surface mount connections
Omit = RoHS 5/6, Lead Based Solder Used
Z Z = RoHS 6/6 Compliant, Lead free
RoHS
Asia-Pacific Headquarters
Tel: +65 6593 7211
Europe, Middle-East and Africa Headquarters
Tel: +49 89 878067-280
World Wide Headquarters
Lineage Power Corporation
601 Shiloh Road, Plano, TX 75074, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-244-9428)
www.lineagepower.com
India Headquarters
Tel: +91 80 28411633
e-mail: techsupport1@lineagepower.com
Lineage Power reser ves the right to make c hanges to the product(s) or information contained herei n without notice. N o liability is ass umed as a res ult of their use or
application. No rights under any patent accompany the sale of any suc h produc t(s) or infor mati on.
Lineage Power DC-DC products are protected under various patents. Information on these patents is availabl e at www.lineagepower.com/patents.
© 2011 Lineage Power Corporation, (Plano, Texas) All International Rights Reser ved.
Document No: DS09-013 ver.1.01
PDF name: ESTW025A0F.pdf