 浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第1页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第3页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第4页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第5页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第6页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第7页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第8页浏览型号ESTW025A0F41-HZ的Datasheet PDF文件第9页  
Data Sheet
October 11, 2011
ESTW025A0F Series Eighth-Brick Power Modules
36–75Vdc Input; 3.3Vdc Output; 25A Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient, operational (≤100 ms)
Operating Ambient Temperature
Maximum Base-plate Operating Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation voltage (100% factory Hi-Pot tested)
All
All
T
stg
-55
125
2250
°C
V
dc
All
All
All
-18H, H
V
IN
V
IN,trans
T
A
T
C
-0.3
-0.3
-40
-40
80
100
85
110
V
dc
V
dc
°C
°C
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
)
Input No Load Current
(V
IN
= V
IN, nom
, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= V
IN, nom
, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to V
IN, max,
I
O
= I
Omax
; See Test configuration section)
Input Ripple Rejection (120Hz)
Device
All
All
All
All
All
Symbol
V
IN
I
IN,max
I
IN,No load
I
IN,stand-by
It
2
Min
36
Typ
48
Max
75
2.7
Unit
V
dc
A
dc
mA
50
6
8
1
mA
As
2
All
30
mA
p-p
All
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2