EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
EQW  
VIN  
-0.3  
80  
Vdc  
Continuous  
Transient (100ms)  
EQW  
All  
VIN, trans  
TA  
-0.3  
-40  
100  
85  
Vdc  
°C  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
All  
All  
Tstg  
-55  
125  
°C  
I/O Isolation Voltage (100% factory Hi-Pot tested)  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
All  
Symbol  
VIN  
Min  
Typ  
Max  
75  
3
Unit  
Vdc  
Operating Input Voltage  
Maximum Input Current  
(VIN=0V to 75V, IO=IO, max  
Input No Load Current  
36  
48  
All  
IIN,max  
Adc  
)
All  
All  
IIN,No load  
75  
3
mA  
mA  
(Vin = 48Vdc, Io = 0, module enabled)  
Input Stand-by Current  
IIN,stand-by  
(Vin = 48Vdc, module disabled)  
Inrush Transient  
All  
All  
All  
I2t  
1
A2s  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V  
to 75V, IO= IOmax ; see Test Configuration section)  
13  
50  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
EMC, EN55022  
See EMC Considerations section  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a fast-acting fuse with a maximum rating of 6A (see Safety Considerations section). Based on the information  
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating  
can be used. Refer to the fuse manufacturer’s data sheet for further information.  
LINEAGE POWER  