Data Sheet  
EQW006 Series, Eight Brick Power Modules: DC-DC Converter  
36 – 75Vdc Input; 12Vdc Output; 6A Output Current  
March 26, 2008  
Safety Considerations  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standard, i.e., UL60950, CSA C22.2 No. 60950-00  
and VDE 0805:2001-12 (IEC60950, 3rd Ed).  
These converters have been evaluated to the spacing  
requirements for Basic Insulation, per the above  
safety standards; and 1500 Vdc is applied from Vi to  
Vo to 100% of outgoing production.  
For all input voltages, other than DC MAINS, where  
the input voltage is less than 60V dc, if the input  
meets all of the requirements for SELV, then:  
The output may be considered SELV. Output  
voltages will remain within SELV limits even with  
internally-generated non-SELV voltages. Single  
component failure and fault tests were performed  
in the power converters.  
One pole of the input and one pole of the output  
are to be grounded, or both circuits are to be kept  
floating, to maintain the output voltage to ground  
voltage within ELV or SELV limits.  
For all input sources, other than DC MAINS, where  
the input voltage is between 60 and 75V dc  
(Classified as TNV-2 in Europe), the following must  
be adhered to, if the converter’s output is to be  
evaluated for SELV:  
The input source is to be provided with reinforced  
insulation from any hazardous voltage, including  
the AC mains.  
One Vi pin and one Vo pin are to be reliably  
earthed, or both the input and output pins are to  
be kept floating.  
Another SELV reliability test is conducted on the  
whole system, as required by the safety  
agencies, on the combination of supply source  
and the subject module to verify that under a  
single fault, hazardous voltages do not appear at  
the module’s output.  
The power module has ELV (extra-low voltage)  
outputs when all inputs are ELV.  
All flammable materials used in the manufacturing of  
these modules are rated 94V-0, and UL60950 A.2 for  
reduced thickness. The input to these units is to be  
provided with a maximum 6A time- delay in the  
unearthed lead.  