Data Sheet  
EQD020 Series Single Output: Eighth Brick Power Modules:  
19-60Vdc Input; 3.3Vdc Output; 66W  
November 9, 2006  
Over Temperature Protection  
Feature Descriptions  
These modules feature an overtemperature protection  
circuit to safeguard against thermal damage. The  
Remote On/Off  
The EQD020 series power modules have primary  
referenced remote On/Off. The remote on/off is open  
collector compatible with the signal common  
circuit shuts down and latches off the module when  
the maximum device reference temperature is  
exceeded. The module can be restarted by cycling  
the dc input power for at least one second or by  
toggling the remote on/off signal for at least one  
second. If the auto-restart option (4) is ordered, the  
module will automatically restart upon cool-down to a  
safe temperature.  
referenced to the negative input. The standard  
remote on/off negative logic is such that a unit  
operates (ON) when the remote on/off signal is low or  
short circuit to minus VIN. A module will be OFF when  
the remote on/off pin is open circuit or when the  
remote on/off signal is high. Observe the maximum  
external ON/OFF voltage, specified in the Feature  
Specifications table, when connecting an external  
source to the ON/OFF pin. The optional positive logic  
remote on/off is such that a unit operates (ON) when  
the remote on/off signal is high or open-circuit. A unit  
will be OFF when the remote on/off signal is low or  
short-circuited to minus VIN.  
Output Over Voltage Protection  
The output over voltage protection scheme of the  
modules has an independent over voltage loop to  
prevent single point of failure. This protection feature  
latches in the event of over voltage across the output.  
Cycling the on/off pin or input voltage resets the  
latching protection feature. If the auto-restart option  
(4) is ordered, the module will automatically restart  
upon an internally programmed time elapsing.  
VIN(+)  
Remote sense  
The EQD020 series power modules have a Remote  
Sense feature to minimize the effects of distribution  
losses by regulating the voltage at the Remote Sense  
pin (See Figure 20). The voltage between the Sense  
pin and Vo pin must not exceed 0.33V.  
VO  
Ion/off  
ON/OFF  
Von/off  
COM  
The amount of power delivered by the module is  
defined as the output voltage multiplied by the output  
current (Vo x Io). When using Remote Sense, the  
output voltage of the module can increase, which, if  
the same output is maintained, increases the power  
output from the module. Make sure that the maximum  
output power of the module remains at or below the  
maximum rated power. When the Remote Sense  
feature is not being used, connect the Remote Sense  
pins to the output pins of the module.  
VIN(-)  
Figure 19. Circuit configuration for using Remote  
On/Off Implementation.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current  
limiting continuously. At the point of current-limit  
inception, the unit enters a hiccup mode. If the unit is  
not configured with auto–restart, then it will latch off  
following the over current condition. The module can  
be restarted by cycling the dc input power for at least  
one second or by toggling the remote on/off signal for  
at least one second. If the unit is configured with the  
auto-restart option (4), it will remain in the hiccup  
mode as long as the overcurrent condition exists; it  
operates normally, once the output current is brought  
back into its specified range.  
SENSE(+)  
SENSE(–)  
V
I
(+)  
VO(+)  
I
O
SUPPLY  
LOAD  
I
I
VI  
(-)  
VO(–)  
CONTACT  
RESISTANCE  
CONTACT AND  
DISTRIBUTION LOSSES  
Figure 20. Effective Circuit Configuration for  
remote sense operation.  
Input Under Voltage Lockout  
At input voltages below the input under voltage  
lockout limit, the module operation is disabled. The  
module will begin to operate at an input voltage above  
the under voltage lockout turn-on threshold.  
Tyco Electronics Power Systems  
9