Technical Requirements
June 27, 2012
EBVW025A0B Series Power Modules; DC-DC Converters
36-75Vdc Input; 9.6-12Vdc Output; 25A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage*
Continuous
VIN
-0.3
75
Vdc
Vdc
Operating transient ≤ 100mS
100
Operating Input transient slew rate, 50VIN to 75VIN
(Output may exceed regulation limits, no protective
-
-
10
V/µs
shutdowns shall activate, CO=220μF to CO, max
)
Non- operating continuous
VIN
TA
80
100
85
Vdc
°C
Operating Ambient Temperature
(See Thermal Considerations section)
Storage Temperature
All
-40
All
All
Tstg
-55
125
°C
I/O Isolation Voltage (100% factory Hi-Pot tested)
2250
Vdc
* Input over voltage protection will shutdown the output voltage, when the input voltage exceeds threshold level.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
VIN
36
48
75
Vdc
Maximum Input Current
(VIN=0V to 75V, IO=IO, max
Input No Load Current
IIN,max
-
-
9
Adc
)
All
All
IIN,No load
50
mA
(VIN = VIN, nom, IO = 0, module enabled)
Input Stand-by Current
IIN,stand-by
25
mA
(VIN = VIN, nom, module disabled)
External Input Capacitance
All
All
100
-
-
-
-
μF
Inrush Transient
I2t
1
A2s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN= 48V,
IO= IOmax ; see Figure 12)
All
All
-
-
24
50
-
-
mAp-p
dB
Input Ripple Rejection (120Hz)
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a
fast-acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in
this Data Sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used.
Refer to the fuse manufacturer’s Data Sheet for further information.