欢迎访问ic37.com |
会员登录 免费注册
发布采购

EBVW020A0B984Z 参数 Datasheet PDF下载

EBVW020A0B984Z图片预览
型号: EBVW020A0B984Z
PDF下载: 下载PDF文件 查看货源
内容描述: [36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output]
分类和应用:
文件页数/大小: 18 页 / 1337 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号EBVW020A0B984Z的Datasheet PDF文件第1页浏览型号EBVW020A0B984Z的Datasheet PDF文件第3页浏览型号EBVW020A0B984Z的Datasheet PDF文件第4页浏览型号EBVW020A0B984Z的Datasheet PDF文件第5页浏览型号EBVW020A0B984Z的Datasheet PDF文件第6页浏览型号EBVW020A0B984Z的Datasheet PDF文件第7页浏览型号EBVW020A0B984Z的Datasheet PDF文件第8页浏览型号EBVW020A0B984Z的Datasheet PDF文件第9页  
Data Sheet  
GE  
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage*  
Continuous  
VIN  
-0.3  
75  
Vdc  
Vdc  
Operating transient 100mS  
100  
Operating Input transient slew rate, 50VIN to 75VIN  
(Output may exceed regulation limits, no protective  
-
-
10  
V/µs  
shutdowns shall activate, CO=220μF to CO, max  
)
Non- operating continuous  
VIN  
TA  
80  
100  
85  
Vdc  
°C  
Operating Ambient Temperature  
(See Thermal Considerations section)  
Storage Temperature  
All  
-40  
All  
All  
Tstg  
-55  
125  
°C  
I/O Isolation Voltage (100% factory Hi-Pot tested)  
2250  
Vdc  
* Input over voltage protection will shutdown the output voltage, when the input voltage exceeds threshold level.  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
Maximum Input Current  
VIN  
36  
48  
75  
Vdc  
IIN,max  
-
-
7
Adc  
(VIN=0V to 75V, IO=IO, max  
)
Input No Load Current  
All  
All  
IIN,No load  
50  
mA  
(VIN = VIN, nom, IO = 0, module enabled)  
Input Stand-by Current  
IIN,stand-by  
25  
mA  
(VIN = VIN, nom, module disabled)  
External Input Capacitance  
All  
All  
100  
-
-
-
-
μF  
Inrush Transient  
I2t  
1
A2s  
Input Terminal Ripple Current  
(Measured at module input pin with maximum specified input  
capacitance and 500uH inductance between voltage source  
and input capacitance CIN=220uF, 5Hz to 20MHz, VIN= 48V, IO=  
All  
-
900  
-
mArms  
IOmax  
)
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN= 48V, IO= IOmax ; see  
Figure 12)  
All  
All  
-
-
24  
50  
-
-
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part  
of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum  
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating  
of 15 A (see Safety Considerations section). Based on the information provided in this Data Sheet on inrush energy and maximum  
dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s Data Sheet for further  
information.  
July 22, 2013  
©2012 General Electric Company. All rights reserved.  
Page 2  