 浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第8页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第9页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第10页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第11页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第13页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第14页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第15页浏览型号EBDW020A0B641-HZ的Datasheet PDF文件第16页  
Data Sheet  
GE  
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
Please refer to the Application Note “Thermal Characterization  
Thermal Considerations (continued)  
Process For Open-Frame Board-Mounted Power Modules” for  
temperature, as defined in IPC-9592. This procedure is then  
a detailed discussion of thermal aspects including maximum  
repeated for a different airflow or ambient temperature until a  
device temperatures.  
family of module output derating curves is obtained.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat transfer  
via convection. The thermal derating of figure 21-23 shows  
the maximum output current that can be delivered by each  
module in the indicated orientation without exceeding the  
maximum THx temperature versus local ambient temperature  
(TA) for several air flow conditions.  
The use of Figure 21 is shown in the following example:  
Example  
What is the minimum airflow necessary for a EBDW020A0B  
operating at VI = 48 V, an output current of 15A, and a  
maximum ambient temperature of 60 °C in transverse  
orientation.  
Solution:  
Velocity = 0.5m/s (100 LFM) or greater.  
Given: Vin= 48V, IO = 14A, TA = 60 °C  
Determine required airflow velocity (Use Figure 21):  
Velocity = 0.5m/s (100 LFM) or greater.  
Heat-dissipating components are mounted on the top side of  
the module. Heat is removed by conduction, convection and  
radiation to the surrounding environment. Proper cooling can  
be verified by measuring the thermal reference temperature  
(TH1 or TH2). Peak temperature occurs at the position indicated  
in Figure 19 and 20. For reliable operation this temperature  
should not exceed TH1=125°C or TH2=105°C. For extremely  
high reliability you can limit this temperature to a lower value.  
LOCAL AMBIENT TEMPERATURE, TA (C)  
Figure 21. Output Current Derating for the Open Frame  
EBDW020A0B in the Transverse Orientation; Airflow  
Direction from Vin(-) to Vin(+); Vin = 48V.  
Figure 19. Location of the thermal reference temperature TH. Do  
not exceed 113 °C.  
Figure 20. Location of the thermal reference temperature  
TH3 for Baseplate module. Do not exceed 110 °C.  
The output power of the module should not exceed the rated  
power for the module as listed in the Ordering Information  
Figure 22. Output Current Derating for the Base Plate  
table.  
LOCAL AMBIENT TEMPERATURE, TA (C)  
EBDW020A0Bxx-H in the Transverse Orientation; Airflow  
Direction from Vin(-) to Vin(+); Vin = 48V.  