欢迎访问ic37.com |
会员登录 免费注册
发布采购

CLP0212FPEXZ02A 参数 Datasheet PDF下载

CLP0212FPEXZ02A图片预览
型号: CLP0212FPEXZ02A
PDF下载: 下载PDF文件 查看货源
内容描述: [90 - 264Vac input; 12Vdc output; 200W Output Power]
分类和应用:
文件页数/大小: 15 页 / 1475 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第3页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第4页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第5页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第6页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第8页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第9页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第10页浏览型号CLP0212FPEXZ02A的Datasheet PDF文件第11页  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Output Voltage Adjustment  
Safety Considerations  
The CLP0212 power supply is intended for inclusion in other  
equipment and the installer must ensure that it is in  
compliance with all the requirements of the end application.  
This product is only for inclusion by professional installers  
within other equipment and must not be operated as a  
stand-alone product  
IEC60950, EN60950, with the following deviations: Nemko  
. The power supply meets Class 1,  
Potentiometer  
.
UL  
60950 (Recognized Component) C-UL (Canadian Approvalby  
UL).  
Feature Descriptions  
Fig. 10. Diagram showing location of the potentiometer  
used to adjust the power supply output voltage.  
Standby Power Supply  
A standby output in the CLP0212 power supply of either 3.3  
or 5V, comes on when AC input in the operating range is  
applied. In the Z02A and Z03A versions of the power supply,  
the standby output is not accessible.  
The output voltage can be adjusted between 11.4V and 12.6V  
using a potentiometer on the power supply. See Fig. 10 for a  
diagram showing location of the potentiometer.  
Remote Sense  
Remote On/Off  
The power supply has both positive and negative remote  
sense connections that can be connected to the positive  
and negative rails of the main output near the load. Care  
should be taken in routing the sense lines to ensure that  
noise is not picked up or that additional filtering elements  
that affect the stability of the power supply are not used.  
The power supply will operate without the remote sense  
connections being made, however if remote sense near the  
load is not used it is recommended that the remote sense  
lines be connected directly to the main output terminals.  
All versions of the CLP0212 power supply except the Z02A  
and Z03A versions feature a TTL-compatible On/Off control  
input. The power supply turns ON when the On/Off input  
goes low, and turns OFF when the input goes high. Note  
that if the On/Off pin is left unconnected, the power supply  
main output remains off.  
Figure 9 shows the circuit configuration for using the On/Off  
pin. Either a suitable semiconductor device such as a BJT or  
FET or a mechanical switch can be used to turn the power  
supply On and Off. The switch must be capable of handling  
the On/Off pin current which may be up to 6mA when  
closed. The switch On voltage drop must also be sufficiently  
small so that the photo diode inside the power supply is  
turned ON when the external switch is ON.  
Overcurrent Protection  
To provide protection in a fault condition (output overload), the  
power supply is equipped with internal current-limiting  
circuitry and can endure current limiting continuously. At the  
point of current-limit inception, the unit enters hiccup mode.  
The power supply operates normally once the output current is  
brought back into its specified range.  
Note that the standby output voltage could be either 3.3V or  
5V depending on the CLP0212 power supply variant  
selected. If no On/Off control is desired, the On/Off pin can  
be externally connected to the COM pin and the power  
supply will automatically turn ON when AC input is within  
range.  
Overvoltage Protection  
Overvoltage protection is a feature of the CLP0212 power  
supply that protects both the load and the power supply from  
an output overvoltage condition. When an overvoltage occurs,  
the power supply shuts down and goes into hiccup mode until  
the overvoltage condition is removed. It is not necessary to  
recycle the input to restart the power supply when this  
protection is activated.  
CLP POWER SUPPLY  
STANDBY OUTPUT  
3.65K  
1K  
Overtemperature Protection  
The CLP0212 also features overtemperature protection in  
order to provide additional protection in a fault condition. The  
power supply is equipped with a thermal shutdown circuit  
which detects excessive internal temperatures and shuts the  
unit down. Once the power supply goes into overtemperature  
shutdown, it will cool before attempting to restart. The  
overtemperature protection circuit will typically activate when  
the unit is operated at 200W output with an ambient  
temperature of 60ºC and 1m/s (200LFM) airflow.  
ON/OFF  
SWITCH  
COM  
Fig. 9. Schematic showing ON/OFF circuitry.  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 7  