Data Sheet  
GE  
CAR2548DC series dc-dc converters  
Input: -36Vdc to -75Vdc; Output: 48Vdc @ 2500W; 3.3Vdc or 5 Vdc @ 1A  
Vin_UV_warn_limit (58): This is another warning flag  
indicating that the input voltage is decreasing dangerously  
close to the low input voltage shutdown level.  
Control and Read accuracy:  
The estimates below are believed to be reasonable under most  
operating conditions. However, these are typical numbers and  
not hard bound values that cannot be exceeded. In most  
nominal operating conditions the returned values are  
significantly better than these estimates.  
Status_word (79): returns two bytes of information. The upper  
byte bit functionality is tabulated in the Status_word section.  
The lower byte bit functionality is identical to Status_byte.  
Fan_speed (D7): This register can be used to ‘read’ the fan  
speed in adjustment percent (0 – 100%) or set the fan speed in  
adjustment percent (0 – 100%). The speed of the fan cannot  
be reduced below what the power supply requires for its  
operation. The register value is the percent number, it is not in  
linear format.  
FUNCTION  
ACCURACY  
± 2%  
± 3%  
Vout_command  
Vout_OV_fault_limit  
Iout_OC_warn_limit  
OT_warn_limit  
Vin_UV_warn_limit  
Vin_UV_fault_limit  
Read_Vout  
± 4% of FL  
± 5C  
± 3%  
Invalid commands or data: The power supply notifies the  
MASTER if a non-supported command has been sent or invalid  
data has been received. Notification is implemented by setting  
the appropriate STATUS and ALARM registers and setting the  
SMBAlert# flag.  
± 3%  
± 2%  
± 4% of FL  
Read_Iout  
± 5C  
±5%  
Read_temperature  
Read_Pout  
If a non-supported read is requested the power supply will  
return all 0x00h.  
EEPROM  
Restart after a lachoff: To restart after a latch_off either of  
four restart mechanisms are available. The hardware pin  
Remote ON/OFF may be turned OFF and then ON. The unit  
may be commanded to restart via i2c through the Operation  
command by first turning OFF then turning ON . The third way  
to restart is to remove and reinsert the unit. The fourth way is  
to turn OFF and then turn ON ac power to the unit. The fifth  
way is by changing firmware from latch off to restart. Each of  
these commands must keep the power supply in the OFF state  
for at least 2 seconds, with the exception of changing to  
restart.  
The microcontroller has 96 bytes of EEPROM memory available  
for the system host.  
A separate EEPROM IC, with write protect features, provides  
another 128 bytes of memory. This EEPROM contains the  
following FRU_ID information:  
EEPROM: model number, revision, date code, serial number etc.  
Offset Length Value  
Description  
00  
07  
08  
0C  
0D  
1E  
1F  
20-FF  
7
1
4
1
17  
1
Serial number  
ASCII space  
Date code [YY,WW], ASCII numeric value  
ASCII space  
Model#, ASCII alphanumeric value  
ASCII space  
Revision, ASCII value  
20  
20  
20  
FF  
A successful restart shall clear all alarm registers.  
A power system that is comprised of a number of power  
supplies could have difficulty restarting after a shutdown event  
because of the non-synchronized behavior of the individual  
power supplies. Implementing the latch-off mechanism  
permits a synchronized restart that guarantees the  
simultaneous restart of the entire system.  
1
224  
LEDs  
A synchronous restart can be implemented by;  
Three LEDs are located on the front faceplate. When the LEDs  
are ON GREEN then input and output are normal.  
1. Issuing a GLOBAL OFF and then ON command to all power  
supplies,  
When the FAULT_LED is RED then a fault condition exists and  
the power supply may not provide output power. The table  
below further defines these states:  
2. Toggling Off and then ON the Remote ON/OFF signal  
3. Removing and reapplying input commercial power to the  
entire system.  
It is good practice to turn OFF the power supplies for about 20  
– 30 seconds in order to discharge all internal bias supplies  
and reset the soft start circuitry of the individual power  
supplies.  