欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAR0812DC 参数 Datasheet PDF下载

CAR0812DC图片预览
型号: CAR0812DC
PDF下载: 下载PDF文件 查看货源
内容描述: [Reverse input voltage protection Remote ON/OFF control of the 12VDC output]
分类和应用:
文件页数/大小: 16 页 / 480 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号CAR0812DC的Datasheet PDF文件第1页浏览型号CAR0812DC的Datasheet PDF文件第3页浏览型号CAR0812DC的Datasheet PDF文件第4页浏览型号CAR0812DC的Datasheet PDF文件第5页浏览型号CAR0812DC的Datasheet PDF文件第6页浏览型号CAR0812DC的Datasheet PDF文件第7页浏览型号CAR0812DC的Datasheet PDF文件第8页浏览型号CAR0812DC的Datasheet PDF文件第9页  
Data Sheet  
GE  
CAR0812DC Series DC-DC Converter  
Input: -36VDC to -75VDC; Output: +12 VDC @ 850W; 3.3VDC or 5 VDC @ 1A  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.  
Parameter  
Symbol  
VIN  
Min  
+0.3  
-10  
Max  
-75  
701  
Unit  
VDC  
°C  
Input Voltage: Continuous  
Operating Ambient Temperature  
Storage Temperature  
TA  
Tstg  
-40  
85  
°C  
I/O Isolation voltage (100% factory Hi-Pot tested)  
1500  
VDC  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.  
INPUT  
Parameter  
Symbol  
Min  
-36  
-32  
-33  
Typ  
-48/60  
-33  
Max  
-75  
-35  
-36  
Unit  
VDC  
VDC  
VDC  
Operational Range  
VIN  
VIN  
VIN  
12VDC output turned OFF  
12VDC turned ON  
-35  
Maximum Input Current  
IIN  
IIN  
27.1  
40  
ADC  
(VIN= -36VDC, VOUT= VO, set, IOUT=IO, max  
Cold Start Inrush Current  
(Excluding x-caps, 25C, <10ms, per ETSI 300-132)  
)
Apeak  
Efficiency (TAMB=25C, VIN=-48VDC, VOUT=12VDC  
)
80  
10% load  
20% load  
50% load  
100% load  
88  
92  
89  
%
T
22  
ms  
VDC  
Holdup time – 12VDC(Tamb 25C, VIN -48VDC, Cext 5,000µf)  
Isolation TAMB=25C, VIN=-48VDC, VOUT=12VDC - Input/Output  
Input/Frame  
1500  
1500  
100  
1 minute per IEC/EN 60950-1) Output/Frame  
Ground lug  
Connection required to meet EMI performance  
12Vdc MAIN OUTPUT  
Parameter  
Symbol  
Min  
Typ  
Max  
Unit  
Output power  
POUT  
0
11.98  
-3  
850  
12.02  
+3  
WDC  
VDC  
%
Set point  
12.00  
Overall regulation (load, temperature, aging)  
Ripple and noise3  
VOUT  
120  
+3  
mVp-p  
%
Turn-ON overshoot  
Turn-ON delay  
T
2
sec  
1 Derated above 50C at 2.5%/C  
2
Full load, with 5,000µf external capacitance, 12Vdc set point, droop to 10.8Vdc permitted, > -48Vdc input  
3 Measured across a 10µf tantalum and a 0.1µf ceramic capacitors in parallel. For Vin > 60Vdc the PARD is relaxed to 150mVp-p  
.
April 23, 2013  
©2013 General Electric Company. All rights reserved.  
Page 2  