Austin LynxTM SIP Non-Isolated dc-dc Power Modules:  
3.0 Vdc - 5.5 Vdc Input, 0.9 Vdc - 3.3 Vdc Output, 10 A  
Data Sheet  
March 28, 2008  
Convection Requirements for cooling  
Thermal Considerations  
To predict the approximate cooling needed for the module,  
refer to the Power Derating curves in Figures 26 and 27.  
The power module operates in a variety of thermal environ-  
ments; however, sufficient cooling should be provided to  
help ensure reliable operation of the unit. Heat is removed  
by conduction, convection, and radiation to the surrounding  
environment.  
The thermal data presented is based on measurements  
taken in a wind tunnel. The test setup shown in Figure 25  
was used to collect data for Figures 26  
These derating curves are approximations of the ambient  
temperatures and airflows required to keep the power mod-  
ule temperature below its maximum rating. Once the module  
is assembled in the actual system, the module’s temperature  
should be checked as shown in Figure 24 to ensure it does  
not exceed 110 °C.  
and 27. Note that the airflow is parallel to the long axis of the  
module as shown in Figure 24 and derating applies accord-  
ingly.  
Proper cooling can be verified by measuring the power mod-  
ule’s temperature at Q1-pin 6 and Q2-pin 6 as shown in Fig-  
ure 24.  
11  
10  
9
Pin 6  
8
7
Q2  
Q1  
6
2.0 m/s (400 ft./min.)  
1.0 m/s (200 ft./min.)  
5
4
3
2
1
0
0.5 m/s (100 ft./min.)  
NATURAL CONVECTION  
Airflow  
20  
30  
40  
50  
60  
70  
A
80  
90  
LOCAL AMBIENT TEMPERATURE, T  
(˚C)  
Figure 24. Temperature Measurement Location .  
Figure 26. Typical Power Derating vs output Current  
for 3.3 Vin.  
The temperature at either location should not exceed  
110 °C. The output power of the module should not exceed  
the rated power for the module (VO, set x IO, max).  
11  
10  
9
Wind Tunnel  
25.4  
(1.0)  
8
7
6
PWBs  
2.0 m/s (400 ft./min.)  
1.0 m/s (200 ft./min.)  
Power Module  
5
0.5 m/s (100 ft./min.)  
NATURAL CONVECTION  
4
3
2
1
0
20  
30  
40  
50  
60  
70  
(˚C)  
80  
90  
LOCAL AMBIENT TEMPERATURE, T  
A
76.2  
(3.0)  
Figure 27. Typical Power Derating vs output Current  
for 5.0 Vin.  
x
Probe Location  
for measuring  
airflow and  
12.7  
(0.50)  
ambient  
temperature  
Air  
flow  
Figure 25. Thermal Test Setup.  
Lineage Power  
12