Data Sheet  
12V Austin LynxTM SMT Non-isolated Power Modules Programmable:  
10 – 14 Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current  
April 8, 2008  
Design Considerations (continued)  
Safety Considerations  
For safety agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards,  
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE  
0850:2001-12 (EN60950-1) Licensed.  
Output Filtering  
The 12V Austin Lynx Programmable SMT module is  
designed for low output ripple voltage and will meet the  
maximum output ripple specification with 1 µF ceramic  
and 10 µF tantalum capacitors at the output of the  
module. However, additional output filtering may be  
required by the system designer for a number of reasons.  
First, there may be a need to further reduce the output  
ripple and noise of the module. Second, the dynamic  
response characteristics may need to be customized to a  
particular load step change.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
The input to these units is to be provided with a fast-  
acting fuse with a maximum rating of 15A in the positive  
input lead.  
To reduce the output ripple and improve the dynamic  
response to a step load change, additional capacitance at  
the output can be used. Low ESR polymer and ceramic  
capacitors are recommended to improve the dynamic  
response of the module. For stable operation of the  
module, limit the capacitance to less than the maximum  
output capacitance as specified in the electrical  
specification table.  
LINEAGE POWER  
11