Data Sheet  
12V Austin LynxTM SIP Non-isolated Power Modules, Programmable:  
10Vdc – 14Vdc input; 0.75Vdc to 5.5Vdc Output;10A Output Current  
March 30, 2008  
Feature Description  
Overtemperature Protection  
Remote On/Off  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shutdown if the thermal reference point Tref, exceeds  
125oC (typical), but the thermal shutdown is not  
intended as a guarantee that the unit will survive  
temperatures beyond its rating. The module will  
automatically restarts after it cools down.  
The 12V Austin Lynx Programmable SIP power  
modules feature an On/Off pin for remote On/Off  
operation. If not using the remote On/Off pin, leave the  
pin open (module will be On). The On/Off pin signal  
(Von/Off) is referenced to ground. To switch the module  
on and off using remote On/Off, connect an open  
collector npn transistor between the On/Off pin and the  
ground pin (See Figure 27).  
During a logic-high (On/Off pin is pulled high internal to  
the module) when the transistor is in the Off state, the  
power module is ON. The maximum allowable leakage  
current of the transistor when Von/off = VIN,max is 10µA.  
During a logic-low when the transistor is turned-on, the  
power module is OFF. During this state VOn/Off is less  
than 0.3V and the maximum IOn/Off = 1mA.  
VIN+  
MODULE  
R2  
ON/OFF  
Q2  
+
R1  
V
ON/OFF  
I
ON/OFF  
PWM Enable  
R3  
R4  
Q1  
Q3  
CSS  
GND  
_
Figure 27. Circuit configuration for using positive  
logic On/OFF.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally  
once the output current is brought back into its specified  
range. The typical average output current during hiccup  
is 3A.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  