Data Sheet  
Austin MicroLynxTM 12V SMT Non-isolated Power Modules:  
10 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A output current  
April 1, 2008  
Design Considerations (continued)  
Safety Considerations  
For safety agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards,  
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE  
0850:2001-12 (EN60950-1) Licensed.  
Output Filtering  
The Austin MicroLynxTM 12V module is designed for low  
output ripple voltage and will meet the maximum output  
ripple specification with 1 µF ceramic and 10 µF polymer  
capacitors at the output of the module. However,  
additional output filtering may be required by the system  
designer for a number of reasons. First, there may be a  
need to further reduce the output ripple and noise of the  
module. Second, the dynamic response characteristics  
may need to be customized to a particular load step  
change.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
The input to these units is to be provided with a fast-  
acting fuse with a maximum rating of 6A in the positive  
input lead.  
To reduce the output ripple and improve the dynamic  
response to a step load change, additional capacitance at  
the output can be used. Low ESR polymer and ceramic  
capacitors are recommended to improve the dynamic  
response of the module. For stable operation of the  
module, limit the capacitance to less than the maximum  
output capacitance as specified in the electrical  
specification table.  
LINEAGE POWER  