Data Sheet
Austin MicroLynxTM 12V SIP Non-isolated Power Modules:
10 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A output current
April 1, 2008
Design Considerations (continued)
Safety Considerations
For safety agency approval the power module must
be installed in compliance with the spacing and
separation requirements of the end-use safety agency
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-1-
03, and VDE 0850:2001-12 (EN60950-1) Licensed.
Output Filtering
The Austin MicroLynxTM 12V SIP module is designed
for low output ripple voltage and will meet the
maximum output ripple specification with 1 µF
ceramic and 10 µF polymer capacitors at the output of
the module. However, additional output filtering may
be required by the system designer for a number of
reasons. First, there may be a need to further reduce
the output ripple and noise of the module. Second,
the dynamic response characteristics may need to be
customized to a particular load step change.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 6A in the
positive input lead.
To reduce the output ripple and improve the dynamic
response to a step load change, additional
capacitance at the output can be used. Low ESR
polymer and ceramic capacitors are recommended to
improve the dynamic response of the module. For
stable operation of the module, limit the capacitance
to less than the maximum output capacitance as
specified in the electrical specification table.
LINEAGE POWER
11
Document No: DS03-101 ver. 1.31
PDF name: microlynx_12v_sip_ds.pdf