 浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第15页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第16页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第17页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第18页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第20页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第21页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第22页浏览型号ATS030A0X3-SRHZ的Datasheet PDF文件第23页  
Data Sheet  
Austin MegaLynxTM SMT: Non-Isolated DC-DC Power Modules:  
4.5 – 5.5Vdc input; 0.8 to 3.63Vdc Output; 30A output current  
6.0 – 14Vdc Input; 0.8Vdc to 3.63Vdc Output; 20/30A output  
June 3, 2009  
The thermal reference points, Tref used in the  
specifications are shown in Figure 56. For reliable  
operation the temperatures at these points should  
not exceed 125oC. The output power of the module  
should not exceed the rated power of the module  
(Vo,set x Io,max).  
Thermal Considerations  
Power modules operate in a variety of thermal  
environments; however, sufficient cooling should  
always be provided to help ensure reliable  
operation.  
Considerations include ambient temperature,  
airflow, module power dissipation, and the need for  
increased reliability. A reduction in the operating  
temperature of the module will result in an increase  
in reliability. The thermal data presented here is  
based on physical measurements taken in a wind  
tunnel. The test set-up is shown in Figure 54. Note  
that the airflow is parallel to the short axis of the  
module as shown in Figure 55. The derating data  
applies to airflow in either direction of the module’s  
long axis.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion  
of thermal aspects including maximum device  
temperatures.  
25.4_  
(1.0)  
Wind Tunnel  
PWBs  
Power Module  
Figure 55. Airflow direction for thermal testing.  
76.2_  
(3.0)  
x
Probe Location  
for measuring  
airflow and  
12.7_  
(0.50)  
ambient  
temperature  
Figure 56. T  
location.  
Temperature measurement  
ref  
Air  
flow  
Figure 54. Thermal Test Setup.  