Data Sheet  
Austin MegaLynxTM Non-Isolated dc-dc Power Modules:  
4.5 – 5.5Vdc input; 0.8 – 3.63Vdc output; 30A output current  
6.0 – 14Vdc input; 0.8 – 5.5Vdc output; 25A output current  
June 3, 2009  
For proper voltage sequencing, first, input voltage is  
applied to the module. The On/Off pin of the module is  
left unconnected or tied to GND for negative logic  
modules so that the module is ON by default. After  
applying input voltage to the module, a delay of 10msec  
minimum is required before applying voltage on the SEQ  
pin. During this delay time, the SEQ pin should be kept  
at a voltage of 50mV (± 20 mV). After the 10msec delay,  
the voltage applied to the SEQ pin is allowed to vary and  
the output voltage of the module will track this voltage on  
a one-to-one volt basis until the output reaches the set-  
point voltage. To initiate simultaneous shutdown of the  
modules, the sequence pin voltage is lowered in a  
controlled manner. The output voltages of the modules  
track the sequence pin voltage when it falls below their  
set-point voltages. A valid input voltage must be  
not be equal. To allow for such variation and avoid  
the likelihood of a converter shutting off due to a  
current overload, the total capacity of the paralleled  
system should be no more than 75% of the sum of  
the individual converters. As an example, for a  
system of four ATS030A0X3-SR converters the  
parallel, the total current drawn should be less that  
75% of (4 x 30A) , i.e. less than 90A.  
All modules should be turned on and off together.  
This is so that all modules come up at the same time  
avoiding the problem of one converter sourcing  
current into the other leading to an overcurrent trip  
condition. To ensure that all modules come up  
simultaneously, the on/off pins of all paralleled  
converters should be tied together and the  
converters enabled and disabled using the on/off  
pin.  
maintained until the tracking and output voltages reach  
zero to ensure a controlled shutdown of the modules.  
For a more detailed description of sequencing, please  
refer to Application Note AN04-008 titled “Guidelines  
for Sequencing of Multiple Modules”.  
The share bus is not designed for redundant  
operation and the system will be non-functional  
upon failure of one of the unit when multiple units  
are in parallel. In particular, if one of the converters  
shuts down during operation, the other converters  
may also shut down due to their outputs hitting  
current limit. In such a situation, unless a  
coordinated restart is ensured, the system may  
never properly restart since different converters will  
try to restart at different times causing an overload  
condition and subsequent shutdown. This situation  
can be avoided by having an external output voltage  
monitor circuit that detects a shutdown condition  
and forces all converters to shut down and restart  
together.  
When using the EZ-SEQUENCETM feature to control  
start-up of the module, pre-bias immunity feature during  
start-up is disabled. The pre-bias immunity feature of  
the module relies on the module being in the diode-mode  
during start-up. When using the EZ-SEQUENCETM  
feature, modules goes through an internal set-up time of  
10msec, and will be in synchronous rectification mode  
when voltage at the SEQ pin is applied. This will result  
in sinking current in the module if pre-bias voltage is  
present at the output of the module. When pre-bias  
immunity during start-up is required, the EZ-  
SEQUENCETM feature must be disabled.  
Active Load Sharing (-P Option)  
For additional power requirements, the Austin MegaLynx  
series power module is also available with a parallel  
option. Up to five modules can be configured, in parallel,  
with active load sharing. Good layout techniques should  
be observed when using multiple units in parallel. To  
implement forced load sharing, the following connections  
should be made:  
The share pins of all units in parallel must be  
connected together. The path of these connections  
should be as direct as possible.  
All remote-sense pins should be connected to the  
power bus at the same point, i.e., connect all the  
SENSE(+) pins to the (+) side of the bus. Close  
proximity and directness are necessary for good  
noise immunity  
Some special considerations apply for design of  
converters in parallel operation:  
When sizing the number of modules required for  
parallel operation, take note of the fact that current  
sharing has some tolerance. In addition, under  
transient condtions such as a dynamic load change  
and during startup, all converter output currents will  
LINEAGE POWER  
15  