 浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第9页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第10页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第11页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第12页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第14页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第15页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第16页浏览型号ATM030A0X3-SRPHZ的Datasheet PDF文件第17页  
Data Sheet  
Austin MegaLynxTM SMT: Non-Isolated DC-DC Power Modules:  
2.7 – 4.0Vdc input; 0.8 to 2.0Vdc Output; 30A output current  
October 21, 2009  
at the SEQ pin is applied. This will result in sinking  
current in the module if pre-bias voltage is present  
at the output of the module. When pre-bias  
immunity during start-up is required, the EZ-  
SEQUENCETM feature must be disabled. For  
additional guidelines on using EZ-SEQUENCETM  
feature of Austin MegaLynx modules, contact the  
Tyco Power Systems Technical representative for  
the application note on output voltage sequencing.  
All modules should be turned on and off  
together. This is so that all modules come up at  
the same time avoiding the problem of one  
converter sourcing current into the other  
leading to an overcurrent trip condition. To  
ensure that all modules come up  
simultaneously, the on/off pins of all paralleled  
converters should be tied together and the  
converters enabled and disabled using the  
on/off pin.  
Active Load Sharing (-P Option)  
The share bus is not designed for redundant  
operation and the system will be non-functional  
upon failure of one of the unit when multiple  
units are in parallel. In particular, if one of the  
converters shuts down during operation, the  
other converters may also shut down due to  
their outputs hitting current limit. In such a  
situation, unless a coordinated restart is  
ensured, the system may never properly restart  
since different converters will try to restart at  
different times causing an overload condition  
and subsequent shutdown. This situation can  
be avoided by having an external output  
voltage monitor circuit that detects a shutdown  
condition and forces all converters to shut  
down and restart together.  
For additional power requirements, the ATM030  
series power module is also available with a parallel  
option. Up to five modules can be configured, in  
parallel, with active load sharing. Good layout  
techniques should be observed when using multiple  
units in parallel. To implement forced load sharing,  
the following connections should be made:  
The share pins of all units in parallel must be  
connected together. The path of these  
connections should be as direct as possible.  
All remote-sense pins should be connected to  
the power bus at the same point, i.e., connect  
all the SENSE(+) pins to the (+) side of the bus.  
Close proximity and directness are necessary  
for good noise immunity  
When not using the parallel feature, leave the share  
pin open.  
Some special considerations apply for design of  
converters in parallel operation:  
When sizing the number of modules required for  
parallel operation, take note of the fact that current  
sharing has some tolerance. In addition, under  
transient condtions such as a dynamic load change  
and during startup, all converter output currents will  
not be equal. To allow for such variation and avoid  
the likelihood of a converter shutting off due to a  
current overload, the total capacity of the paralleled  
system should be no more than 75% of the sum of  
the individual converters. As an example, for a  
system of four ATM030A0X3-SR converters the  
parallel, the total current drawn should be less that  
75% of 4 x 30A or 90A.  
When sizing the number of modules required  
for parallel operation, take note of the fact that  
current sharing has some tolerance. In  
addition, under transient condtions such as a  
dynamic load change and during startup, all  
converter output currents will not be equal. To  
allow for such variation and avoid the likelihood  
of a converter shutting off due to a current  
overload, the total capacity of the paralleled  
system should be no more than 75% of the  
sum of the individual converters. As an  
example, for a system of four ATM030A0X3-  
SR converters the parallel, the total current  
drawn should be less that 75% of (4 x 30A) ,  
i.e. less than 90A.  
LINEAGE POWER  
13