 浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第11页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第12页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第13页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第14页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第16页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第17页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第18页浏览型号ATL010A0X43-SRZ的Datasheet PDF文件第19页  
Data Sheet  
ATL010A0X43-SR Non Isolated Module 12Vdc, Programmable:  
9 – 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current  
April 1, 2008  
Thermal Considerations  
Power modules operate in a variety of thermal  
environments; however sufficient cooling should always  
be provided to help ensure reliable operation.  
25.4_  
(1.0)  
Wind Tunnel  
PWBs  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of the  
module will result in an increase in reliability. The thermal  
data presented here is based on physical measurements  
taken in a wind tunnel. The test set-up is shown in Figure  
32. Note that the airflow is parallel to the short axis of the  
module as shown in figure 31. The derating data applies  
to airflow in either direction of the module’s short axis.  
Powe r Mo d ule  
76.2_  
(3.0)  
x
Pro b e Lo c a tio n  
for measuring  
airflow and  
ambient  
8.3_  
(0.325)  
temperature  
Air  
flow  
Tref1  
Tref2  
Figure 32. Thermal Test Set-up.  
Bottom View  
Figure 31. Temperature measurement locations Tref1  
Heat Transfer via Convection  
and Tref2  
.
Increased airflow over the module enhances the heat  
transfer via convection. Thermal derating curves showing  
the maximum output current that can be delivered at  
different local ambient temperatures (TA) for airflow  
conditions ranging from natural convection and up to  
2m/s (400 ft./min) are shown in the Characteristics  
Curves section.  
The thermal reference points, Tref1 and Tref2 used in the  
specifications are shown in Figure 31. For reliable  
operation these temperatures should not exceed 115oC.  
The output power of the module should not exceed the  
rated power of the module (Vo,set x Io,max).  
Please refer to the Application Note “Thermal  
Layout Considerations  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device temperatures.  
Copper paths must not be routed beneath the power  
module. For additional layout guide-lines, refer to the  
FLTR100V10 application note.  
LINEAGE POWER  