欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATL010A0X43-SR 参数 Datasheet PDF下载

ATL010A0X43-SR图片预览
型号: ATL010A0X43-SR
PDF下载: 下载PDF文件 查看货源
内容描述: 9 - 18VDC输入; 0.75Vdc至5.5VDC输出; 10A的输出电流 [9 - 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current]
分类和应用:
文件页数/大小: 21 页 / 722 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号ATL010A0X43-SR的Datasheet PDF文件第8页浏览型号ATL010A0X43-SR的Datasheet PDF文件第9页浏览型号ATL010A0X43-SR的Datasheet PDF文件第10页浏览型号ATL010A0X43-SR的Datasheet PDF文件第11页浏览型号ATL010A0X43-SR的Datasheet PDF文件第13页浏览型号ATL010A0X43-SR的Datasheet PDF文件第14页浏览型号ATL010A0X43-SR的Datasheet PDF文件第15页浏览型号ATL010A0X43-SR的Datasheet PDF文件第16页  
Data Sheet  
ATL010A0X43-SR Non Isolated Module 12Vdc, Programmable:  
9 – 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current  
April 1, 2008  
Feature Description  
Overtemperature Protection  
Remote On/Off  
To provide over temperature protection in a fault  
The ATL010A0X43-SR power modules feature an On/Off  
pin for remote On/Off operation. The ATL010A0X43-SR  
modules feature positive on/off logic. Positive Logic  
On/Off signal, turns the module ON during a logic High on  
the On/Off pin and turns the module OFF during a logic  
Low.  
condition, the unit relies upon the thermal protection  
feature of the controller IC. The unit will shutdown if the  
thermal reference point Tref, exceeds 125oC (typical), but  
the thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating. The  
module will automatically restart after it cools down.  
For positive logic modules, the circuit configuration for  
using the On/Off pin is shown in Figure 27. The On/Off  
pin is an open collector/drain logic input signal (Von/Off)  
that is referenced to ground. During a logic-high (On/Off  
pin is pulled high internal to the module) when the  
transistor Q1 is in the Off state, the power module is ON.  
Maximum allowable leakage current of the transistor  
when Von/off = VIN,max is 10µA. Applying a logic-low  
when the transistor Q1 is turned-On, the power module is  
OFF. During this state VOn/Off must be less than 0.3V.  
When not using positive logic On/off pin, leave the pin  
unconnected or tie to VIN.  
Output Voltage Programming  
The output voltage of the ATL010A0X43-SR module can  
be programmed to any voltage from 0.75Vdc to 5.0Vdc  
by connecting a resistor (shown as Rtrim in Figure 28)  
between Trim and GND pins of the module. Without an  
external resistor between Trim and GND pins, the output  
of the module will be 0.7525Vdc. To calculate the value  
of the trim resistor, Rtrim for a desired output voltage, use  
the following equation:  
10500  
Rtrim =  
1000 Ω  
Vo 0.7525  
VIN+  
MODULE  
Rtrim is the external resistor in Ω  
Vo is the desired output voltage  
R2  
ON/OFF  
Q2  
For example, to program the output voltage of the  
ATL010A0X43-SR module to 1.8V, Rtrim is calculated as  
follows:  
+
R1  
V
ON/OFF  
I
ON/OFF  
PWM Enable  
10500  
R3  
R4  
Rtrim =  
1000  
1.8 0.75  
Q1  
Q3  
CSS  
Rtrim = 9.024kΩ  
Vout  
GND  
_
VIN(+)  
VO(+)  
Figure 27. Remote On/Off Implementation.  
ON/OFF  
LOAD  
TRIM  
Overcurrent Protection  
R
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
trim  
GND  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally once  
the output current is brought back into its specified range.  
The typical average output current during hiccup is 3 A.  
Figure 28. Circuit configuration for programming  
output voltage using an external resistor.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will begin  
to operate at an input voltage above the undervoltage  
lockout turn-on threshold.  
LINEAGE POWER  
12