 浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第11页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第12页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第13页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第14页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第16页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第17页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第18页浏览型号ATH016A0X43-SRZ的Datasheet PDF文件第19页  
Data Sheet  
Austin SuperlynxTM II SMT Non-isolated Power Modules:  
June 21, 2008  
2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 16A output current  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device temperatures.  
Thermal Considerations  
Power modules operate in a variety of thermal  
environments; however, sufficient cooling should always  
be provided to help ensure reliable operation.  
25.4_  
(1.0)  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of the  
module will result in an increase in reliability. The thermal  
data presented here is based on physical measurements  
taken in a wind tunnel. The test set-up is shown in Figure  
34. Note that the airflow is parallel to the long axis of the  
module as shown in figure 33. The derating data applies  
to airflow in either direction of the module’s long axis.  
Wind Tunnel  
PWBs  
Po we r Mo d ule  
76.2_  
(3.0)  
Top View  
x
Probe Location  
for measuring  
airflow and  
ambient  
5.97_  
(0.235)  
temperature  
Air  
flow  
Tref  
Bottom View  
Figure 34. Thermal Test Set-up.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. Thermal derating curves showing  
the maximum output current that can be delivered at  
different local ambient temperatures (TA) for airflow  
conditions ranging from natural convection and up to  
2m/s (400 ft./min) are shown in the Characteristics  
Curves section.  
Air Flow  
Figure 33. T  
ref  
Temperature measurement location.  
Layout Considerations  
Copper paths must not be routed beneath the power  
module. For additional layout guide-lines, refer to the  
FLTR100V10 application note.  
The thermal reference point, Tref used in the  
specifications is shown in Figure 33. For reliable  
operation this temperature should not exceed 115oC.  
The output power of the module should not exceed the  
rated power of the module (Vo,set x Io,max).  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
LINEAGE POWER  